Factory-Direct Supply of Certified Wires and Conductors for Diverse Industrial Applications
Single Core 8.7/15KV Medium Voltage Aluminum Wire Armoured Cable
Voltage: 8.7/15kV (Um=17.5kV)
Conductor: Copper or aluminum, Class 2 to IEC 60228
Screen: Extruded semi-con + XLPE 4.5mm + copper wire/tape screen
Inner Sheath: PVC separation layer
Armour: Round aluminium wires, 1.6-2.5mm (AWA)
Overall Sheath: PVC Type ST2, MDPE, or LSZH (BS 7835)
Installation: Indoor, outdoor, underground, cable ducts, water
Product Overview
Single Core 8.7/15kV (Um=17.5kV) MV Aluminium Wire Armoured Cable is the mid-range AWA armoured single-core cable serving the globally dominant 15kV distribution class. At 4.5mm XLPE insulation — constant across all cross-sections unlike the graduated 3.8/6.6kV class — this cable provides the mechanical protection of round aluminium wire armour for direct burial, underground duct, and outdoor installations at the most widely deployed MV voltage worldwide. The 15kV class is the standard utility distribution voltage in the US, Australia, Southeast Asia, and the Middle East — and in all of these markets, buried or exposed MV cables require armour per utility construction standards. For underground residential distribution (URD), mine site power networks, and 15kV industrial feeders where the cable route includes buried or exposed sections, the AWA variant is the mandatory specification.
Cable Construction

1. Stranded Aluminum Conductor
2. Semi-conductor Screen
3. XLPE Insulation — 4.5mm, 90°C
4. Copper Wire, Tape Screen
5. Inner PVC Sheath
6. Aluminum Wire Armor
7. Overall Sheath — PVC/MDPE/LSZH
Conductor
Copper stranded Class 2 or aluminium solid/stranded Class 2. Compacted circular per IEC 60228.
Screen + XLPE
Semi-conducting XLPE screen + 4.5mm XLPE insulation (constant). Triple-extruded, PD-free at 1.73U₀.
Copper Screen
Combined copper wires + tape. Carries earth fault current. Cross-section (4.4-10mm²) per system fault level.
Inner PVC Sheath
Extruded PVC separation layer. Prevents galvanic corrosion between copper screen and aluminium armour in buried installations.
Aluminium Wire Armour
Round Al wires 1.6-2.5mm. Non-magnetic — mandatory for single-core. Crush and impact rated per IEC 60502-2.
Overall Sheath
PVC Type ST2, MDPE, or LSZH (BS 7835). UV-stabilised for outdoor exposure. Black.
Technical Characteristics
| Rated Voltage U₀/U (Um) | 8.7/15kV (17.5kV maximum system voltage) |
| Insulation Thickness | 4.5mm (constant, all cross-sections) |
| Max. Conductor Temperature | 90°C (continuous), 250°C (short-circuit, max 5s) |
| Min. Bending Radius | 12 × overall diameter |
| Armour | Round aluminium wires: 1.6mm (25-70), 2.0mm (95-300), 2.5mm (400-630) |
| Metallic Screen | Copper wires + copper tape, combined |
| Sheath Options | PVC Type ST2, MDPE, or LSZH (BS 7835) |
| Installation Environments | Indoor, outdoor, underground, cable ducts, water |
Applicable Standards
| Standard | Scope |
|---|---|
| BS 6622 | British standard for XLPE single-core cables 3.8/6.6kV to 19/33kV. Governs AWA armoured cable construction. |
| IEC 60502-2 | International standard for MV cables 6kV-30kV. 8.7/15kV AWA meets all mechanical and electrical requirements. |
| BS 7835 | LSZH sheathed version for fire-sensitive indoor installations. |
| IEC 60228 | Conductors — Class 2 stranded copper and aluminium. |
Technical Specifications — Single Core 8.7/15kV AWA
4.5mm XLPE insulation (constant). Armour: 1.6mm wire (25-70mm²), 2.0mm (95-300mm²), 2.5mm (400-630mm²). 13 rows, 25-630mm² Cu/Al.
| Cross Section (mm²) | Insul. (mm) | Cu Screen (mm²) | Armour Wire (mm) | Sheath (mm) | O.D. (mm) | Weight Cu (kg/km) | Weight Al (kg/km) |
|---|---|---|---|---|---|---|---|
| 1 × 25 | 4.5 | 4.4 | 1.6 | 1.8 | 30.3 | 1,430 | 1,210 |
| 1 × 35 | 4.5 | 4.7 | 1.6 | 1.9 | 31.5 | 1,630 | 1,310 |
| 1 × 50 | 4.5 | 4.9 | 1.6 | 1.9 | 32.6 | 1,730 | 1,410 |
| 1 × 70 | 4.5 | 5.3 | 1.6 | 1.9 | 34.2 | 1,970 | 1,520 |
| 1 × 95 | 4.5 | 5.7 | 2.0 | 2.0 | 36.8 | 2,370 | 1,770 |
| 1 × 120 | 4.5 | 6.1 | 2.0 | 2.1 | 38.4 | 2,670 | 1,910 |
| 1 × 150 | 4.5 | 6.4 | 2.0 | 2.1 | 40.1 | 3,020 | 2,080 |
| 1 × 185 | 4.5 | 6.8 | 2.0 | 2.2 | 41.8 | 3,420 | 2,240 |
| 1 × 240 | 4.5 | 7.4 | 2.0 | 2.3 | 44.5 | 4,050 | 2,500 |
| 1 × 300 | 4.5 | 7.9 | 2.0 | 2.3 | 46.5 | 4,680 | 2,780 |
| 1 × 400 | 4.5 | 8.5 | 2.5 | 2.5 | 51.8 | 5,970 | 3,430 |
| 1 × 500 | 4.5 | 9.2 | 2.5 | 2.6 | 54.4 | 7,010 | 3,910 |
| 1 × 630 | 4.5 | 10 | 2.5 | 2.7 | 59.8 | 8,480 | 4,420 |
Packaging & Delivery
Export Wooden Drum
Fumigated wooden drums. AWA armoured cables are heavier than unarmoured but lighter than steel wire equivalents.
Moisture Protection
Triple-layer heat-shrink end caps with desiccant. AWA cables require sealed ends — water ingress to armour layer causes galvanic corrosion.
Documentation
PD test certificate, AC voltage test report, armour continuity test, material traceability per BS 6622.
Typical Applications — Single Core 8.7/15kV AWA
Global 15kV Direct Burial
Underground residential and commercial distribution at 15kV class where direct burial mandates armoured cable per utility standards.
Mining MV Networks
Open-pit and underground mining 15kV feeders. AWA withstands mechanical abuse from mobile equipment, rockfall, and blasting vibration.
Industrial Feeder Cables
Factory and processing plant 15kV feeders routed through cable trays and underground ducts where mechanical protection is required.
Substation Interconnections
15kV AWA cables between switchgear and transformers in outdoor substations. Armour protects against weather, wildlife, and maintenance activity.
Water & Wet Soil Installation
Suitable for laying in fresh water and permanently wet soil. MDPE sheath + AWA combination for maximum moisture protection.
Cable Ducts & Trenches
Underground duct banks subject to construction traffic. AWA provides crush resistance that unarmoured cables lack.
Request a Quote
Frequently Asked Questions
As a factory, we offer flexible MOQ depending on the cable type. For standard stock items, MOQ is low; for customized specifications, please contact our sales team for a detailed quote.
Yes, Qiangli cables are manufactured in compliance with international standards such as UL, CE, TUV, and VDE. We provide full test reports and certificates upon request.
Absolutely. We have a dedicated R&D team that can customize cable structure, material, color, and printing to meet your specific project needs.
For standard products, lead time is usually 7-15 days. For large-scale project orders or customized products, it typically ranges from 20 to 30 days.
Yes, we provide free samples for most standard cables. You only need to cover the international courier costs. Contact us to arrange your sample shipment.