Factory-Direct Supply of Certified Wires and Conductors for Diverse Industrial Applications

Power Cable

Single Core 8.7/15KV Medium Voltage Aluminum Wire Armoured Cable

8.7/15kV XLPE Insulated Copper Screen Aluminum Wire Armoured Power Cable

Voltage: 8.7/15kV (Um=17.5kV)
Conductor: Copper or aluminum, Class 2 to IEC 60228
Screen: Extruded semi-con + XLPE 4.5mm + copper wire/tape screen
Inner Sheath: PVC separation layer
Armour: Round aluminium wires, 1.6-2.5mm (AWA)
Overall Sheath: PVC Type ST2, MDPE, or LSZH (BS 7835)
Installation: Indoor, outdoor, underground, cable ducts, water

Product Overview

Single Core 8.7/15kV (Um=17.5kV) MV Aluminium Wire Armoured Cable is the mid-range AWA armoured single-core cable serving the globally dominant 15kV distribution class. At 4.5mm XLPE insulation — constant across all cross-sections unlike the graduated 3.8/6.6kV class — this cable provides the mechanical protection of round aluminium wire armour for direct burial, underground duct, and outdoor installations at the most widely deployed MV voltage worldwide. The 15kV class is the standard utility distribution voltage in the US, Australia, Southeast Asia, and the Middle East — and in all of these markets, buried or exposed MV cables require armour per utility construction standards. For underground residential distribution (URD), mine site power networks, and 15kV industrial feeders where the cable route includes buried or exposed sections, the AWA variant is the mandatory specification.

Cable Construction

MV Single Core 8.7/15kV AWA Cable Cross Section

1. Stranded Aluminum Conductor
2. Semi-conductor Screen
3. XLPE Insulation — 4.5mm, 90°C
4. Copper Wire, Tape Screen
5. Inner PVC Sheath
6. Aluminum Wire Armor
7. Overall Sheath — PVC/MDPE/LSZH

1

Conductor

Copper stranded Class 2 or aluminium solid/stranded Class 2. Compacted circular per IEC 60228.

2

Screen + XLPE

Semi-conducting XLPE screen + 4.5mm XLPE insulation (constant). Triple-extruded, PD-free at 1.73U₀.

3

Copper Screen

Combined copper wires + tape. Carries earth fault current. Cross-section (4.4-10mm²) per system fault level.

4

Inner PVC Sheath

Extruded PVC separation layer. Prevents galvanic corrosion between copper screen and aluminium armour in buried installations.

5

Aluminium Wire Armour

Round Al wires 1.6-2.5mm. Non-magnetic — mandatory for single-core. Crush and impact rated per IEC 60502-2.

6

Overall Sheath

PVC Type ST2, MDPE, or LSZH (BS 7835). UV-stabilised for outdoor exposure. Black.

Technical Characteristics

Rated Voltage U₀/U (Um)8.7/15kV (17.5kV maximum system voltage)
Insulation Thickness4.5mm (constant, all cross-sections)
Max. Conductor Temperature90°C (continuous), 250°C (short-circuit, max 5s)
Min. Bending Radius12 × overall diameter
ArmourRound aluminium wires: 1.6mm (25-70), 2.0mm (95-300), 2.5mm (400-630)
Metallic ScreenCopper wires + copper tape, combined
Sheath OptionsPVC Type ST2, MDPE, or LSZH (BS 7835)
Installation EnvironmentsIndoor, outdoor, underground, cable ducts, water

Applicable Standards

StandardScope
BS 6622British standard for XLPE single-core cables 3.8/6.6kV to 19/33kV. Governs AWA armoured cable construction.
IEC 60502-2International standard for MV cables 6kV-30kV. 8.7/15kV AWA meets all mechanical and electrical requirements.
BS 7835LSZH sheathed version for fire-sensitive indoor installations.
IEC 60228Conductors — Class 2 stranded copper and aluminium.
15kV is the most commonly armoured MV voltage globally. In the US, URD cables at 15kV class are almost universally specified with armour or concentric neutral for direct burial. In Australia and Southeast Asia, 15kV distribution cables running through buried ducts require mechanical armour to protect against construction damage and rodent attack. The AWA variant of this cable is specified wherever the 15kV class must be deployed in physically exposed or buried environments.

Technical Specifications — Single Core 8.7/15kV AWA

4.5mm XLPE insulation (constant). Armour: 1.6mm wire (25-70mm²), 2.0mm (95-300mm²), 2.5mm (400-630mm²). 13 rows, 25-630mm² Cu/Al.

Cross Section
(mm²)
Insul.
(mm)
Cu Screen
(mm²)
Armour
Wire (mm)
Sheath
(mm)
O.D.
(mm)
Weight Cu
(kg/km)
Weight Al
(kg/km)
1 × 254.54.41.61.830.31,4301,210
1 × 354.54.71.61.931.51,6301,310
1 × 504.54.91.61.932.61,7301,410
1 × 704.55.31.61.934.21,9701,520
1 × 954.55.72.02.036.82,3701,770
1 × 1204.56.12.02.138.42,6701,910
1 × 1504.56.42.02.140.13,0202,080
1 × 1854.56.82.02.241.83,4202,240
1 × 2404.57.42.02.344.54,0502,500
1 × 3004.57.92.02.346.54,6802,780
1 × 4004.58.52.52.551.85,9703,430
1 × 5004.59.22.52.654.47,0103,910
1 × 6304.5102.52.759.88,4804,420

Packaging & Delivery

🪵

Export Wooden Drum

Fumigated wooden drums. AWA armoured cables are heavier than unarmoured but lighter than steel wire equivalents.

🛡️

Moisture Protection

Triple-layer heat-shrink end caps with desiccant. AWA cables require sealed ends — water ingress to armour layer causes galvanic corrosion.

📋

Documentation

PD test certificate, AC voltage test report, armour continuity test, material traceability per BS 6622.

Typical Applications — Single Core 8.7/15kV AWA

🌍

Global 15kV Direct Burial

Underground residential and commercial distribution at 15kV class where direct burial mandates armoured cable per utility standards.

⛏️

Mining MV Networks

Open-pit and underground mining 15kV feeders. AWA withstands mechanical abuse from mobile equipment, rockfall, and blasting vibration.

🏭

Industrial Feeder Cables

Factory and processing plant 15kV feeders routed through cable trays and underground ducts where mechanical protection is required.

Substation Interconnections

15kV AWA cables between switchgear and transformers in outdoor substations. Armour protects against weather, wildlife, and maintenance activity.

🌊

Water & Wet Soil Installation

Suitable for laying in fresh water and permanently wet soil. MDPE sheath + AWA combination for maximum moisture protection.

🏗️

Cable Ducts & Trenches

Underground duct banks subject to construction traffic. AWA provides crush resistance that unarmoured cables lack.

Request a Quote

Ready to Work Together? Build a project with us!
This field is required.
This field is required.
Learn More From

Frequently Asked Questions

As a factory, we offer flexible MOQ depending on the cable type. For standard stock items, MOQ is low; for customized specifications, please contact our sales team for a detailed quote.

Yes, Qiangli cables are manufactured in compliance with international standards such as UL, CE, TUV, and VDE. We provide full test reports and certificates upon request.

Absolutely. We have a dedicated R&D team that can customize cable structure, material, color, and printing to meet your specific project needs.

For standard products, lead time is usually 7-15 days. For large-scale project orders or customized products, it typically ranges from 20 to 30 days.

Yes, we provide free samples for most standard cables. You only need to cover the international courier costs. Contact us to arrange your sample shipment.

inquiry@qiangligroup.com +86 153 3220 6813