Factory-Direct Supply of Certified Wires and Conductors for Diverse Industrial Applications

Power Cable

U-1000 RVFV XAV HFG Cable

Power Cable 0,6/1 kV with Cu conductors, XLPE insulated and Double Steel Tape Armoured

Conductor: Copper, Class 1 (≤4mm²) or Class 2 (≥6mm²)
Insulation: XLPE, rated 90°C
Armour: Double steel or aluminium tape
Sheath: PVC, black, low halogen (Cl<15%)
Voltage: 600/1000V (0.6/1kV)
Number of cores: 2-4 cores, 3+reduced per NF C 32-322
Package: Export wooden drum

Product Overview

U-1000 RVFV XAV Cable is a 0.6/1kV XLPE-insulated armored power cable manufactured to the French standard NF C 32-322. Naming: U-1000 = 1000V rating (French designation for 0.6/1kV), R = rigid conductor, V = XLPE insulation, FV = tape armor (steel or aluminium), XAV = indicating aluminium tape option for single-core. It is the French NFC equivalent of the Spanish UNE 21123 RVFV-K — both share identical construction principles: XLPE insulation, double steel or aluminium tape armor, PVC sheath, with aluminium tape mandatory for single-core to avoid eddy current heating. The conductor is Class 1 (solid, 1.5-4mm²) or Class 2 (stranded, 6mm²+), with Class 2 also available for smaller sizes on request.

NFC vs UNE: Two Standards, Same Cable

StandardDesignationKey StandardMarkets
French NFCU-1000 RVFV XAVNF C 32-322France, Francophone Africa, Maghreb
Spanish UNERVFV-KUNE 21123Spain, Latin America
International IECIEC 60502-1 Armored XLPE/PVCIEC 60502-1Global

Cable Construction

1

Copper Conductor

Class 1 solid (1.5-4mm²) or Class 2 stranded (6mm²+). Class 2 available for smaller sizes on request.

2

XLPE Insulation

Cross-linked polyethylene per IEC 60502-1. 90°C continuous, 250°C short-circuit (max 5s).

3

PVC Bedding

Black extruded PVC separation sheath between laid-up cores and armor. Ensures smooth bedding surface.

4

Tape Armour (FV/XAV)

Double steel tape (multi-core) or aluminium tape (single-core mandatory per NFC). 0.2mm for ≤35mm², 0.5mm for ≥50mm².

5

PVC Outer Sheath

Flexible PVC, black. Low halogen (chlorine <15%), flame-retardant per NF C 32-070 C2.

6

Versatile Installation

5×D bend radius. -40°C to +90°C. Direct burial, conduit, open air. Meter-by-meter marking. CPR Eca.

Core Identification (NF C 32-322)

ConfigurationCore Colors
1 xNatural
2 xBlue + Brown
3 GBlue + Brown + Green/Yellow
3 xBrown + Black + Grey
3 x + 1 xBrown + Black + Grey + Blue (reduced)
4 GBrown + Black + Grey + Green/Yellow
4 xBrown + Black + Grey + Blue
5 GBrown + Black + Grey + Blue + Green/Yellow
6 or moreBlack numbered + Green/Yellow

Technical Characteristics

Rated Voltage600/1000V (0.6/1kV)
Max. Conductor Temperature90°C (continuous), 250°C (short-circuit)
Min. Service Temperature-40°C (fixed and protected)
Min. Bending Radius5 × D
Fire PerformanceFlame non-propagation IEC 60332-1, NF C 32-070 C2
Halogen ContentLow halogen — chlorine <15%
CPR ClassEca per EN 50575
Impact ResistanceAG2 Medium severity

Applicable Standards & Certifications

StandardScope
NF C 32-322French national standard for XLPE insulated armored power cables 0.6/1kV. The primary standard for U-1000 RVFV.
NF C 32-070 C2French flame retardancy test — Category 2 bundled cable fire performance. More stringent than single-cable IEC 60332-1.
IEC 60502-1International standard for power cables 1kV-30kV. U-1000 RVFV meets all IEC 60502-1 requirements.
IEC 60332-1-2Flame non-propagation — single cable vertical flame test.
EN 50575CPR fire classification — Eca class. Mandatory for cables sold in EU since July 2017.
UNE 211605Spanish UV resistance certification — accepted for French outdoor installations.
French market specificity: The "G" notation (3G, 4G, 5G) in NF C 32-322 follows the same convention as UNE 21123: all cores including the earth conductor carry the same cross-section. The "x" notation (3x, 4x) indicates standard cores without a dedicated earth, or with a reduced earth in "3x+1x" configurations. French regulations often mandate G-type cables for public buildings and high-occupancy installations.

Technical Specifications — Dimensional Data

All values per NF C 32-322. Dimensions represent maximum values. Armor thickness: 0.2mm (≤35mm²), 0.5mm (≥50mm²). For current ratings and voltage drop data, refer to the RVFV-K specification which uses the same cable construction per IEC 60502-1.

Cross Section
(mm²)
Insulation
(mm)
Armour
(mm)
Min. Sheath
(mm)
Max. Outer Dia.
(mm)
Approx. Weight
(kg/km)
2-Core
2 × 1.50.70.21.311.5230
2 × 2.50.70.21.312.5275
2 × 40.70.21.413.5330
2 × 60.70.21.415.5430
2 × 100.70.21.416.5555
2 × 160.70.21.519770
2 × 250.90.21.622.51,080
2 × 350.90.21.7251,390
3-Core
3 × 1.50.70.21.312255
3 × 2.50.70.21.313305
3 × 40.70.21.414380
3 × 60.70.21.416500
3 × 100.70.21.517.5665
3 × 160.70.21.520930
3 × 250.90.21.6241,325
3 × 350.90.21.726.51,720
3 × 500.90.21.8292,125
3 × 701.10.22.034.53,080
3 × 951.10.52.1404,505
3 × 1201.20.52.344.55,540
3 × 1501.40.52.448.56,655
3 × 1851.60.52.553.58,150
3 × 2401.70.52.76110,575
3 × 3001.80.52.966.513,055
3-Core + Reduced Neutral
3 × 50 + 351.0/0.90.21.9332,730
3 × 70 + 501.1/0.90.22.0363,440
3 × 95 + 501.1/1.00.52.242.55,080
3 × 120 + 701.2/1.10.52.346.56,275
3 × 150 + 701.4/1.10.52.5507,340
3 × 185 + 701.6/1.10.52.6568,975
3 × 240 + 951.7/1.10.52.862.511,435
4-Core
4 × 1.50.70.21.313290
4 × 2.50.70.21.414355
4 × 40.70.21.415440
4 × 60.70.21.417585
4 × 100.70.21.519800
4 × 160.70.21.6221,120
4 × 250.90.21.7261,650
4 × 350.90.21.8292,135
4 × 501.00.21.932.52,745
4 × 701.10.52.1394,295
4 × 951.10.52.344.55,660
4 × 1201.20.52.448.56,880
4 × 1501.40.52.6538,315
4 × 1851.60.52.760.510,510
4 × 2401.70.52.96713,370
4 × 3001.80.53.17316,360
Source data corrections: Reference page "3x50+35" had insulation values "1.0/09" corrected to "1.0/0.9" (missing decimal point). Armor transition from 0.2mm to 0.5mm occurs at 50mm² per NF C 32-322 — reflected in the table above.

Packaging & Delivery

🪵

Export Wooden Drum

Fumigated wooden drums. Standard for international sea freight and container loading.

📦

Coil Packaging

Smaller cross-sections available in coils for cost-efficient short-haul transport and on-site handling.

📋

Custom Packaging

NF C 32-322 compliant marking, custom drum labeling, sequential meter marking. MOQ applies.

Typical Applications

U-1000 RVFV is specified for projects governed by French NFC standards — Francophone Africa, Maghreb, and French-influenced markets:

🏗️

Direct Burial

Underground LV distribution per NF C 32-322. Steel tape armor permits direct burial without additional mechanical protection.

🏭

Industrial Plants

Heavy industrial environments. C2-rated flame performance per NF C 32-070 for factories and processing plants.

🏢

French-Regulated Buildings

Public buildings, high-rises, and infrastructure in France and oversea territories. G-type cables mandated for safety circuits.

🌍

Francophone Africa

Infrastructure projects in West and Central Africa where NF C 32-322 certification is a tender requirement.

Substations & Switchyards

Inter-station connections. XLPE insulation handles elevated ambient temperatures in electrical yards.

🌐

Maghreb Markets

Algeria, Morocco, Tunisia infrastructure projects accepting French NFC certification as equivalent to local standards.

Request a Quote

Ready to Work Together? Build a project with us!
This field is required.
This field is required.
Learn More From

Frequently Asked Questions

As a factory, we offer flexible MOQ depending on the cable type. For standard stock items, MOQ is low; for customized specifications, please contact our sales team for a detailed quote.

Yes, Qiangli cables are manufactured in compliance with international standards such as UL, CE, TUV, and VDE. We provide full test reports and certificates upon request.

Absolutely. We have a dedicated R&D team that can customize cable structure, material, color, and printing to meet your specific project needs.

For standard products, lead time is usually 7-15 days. For large-scale project orders or customized products, it typically ranges from 20 to 30 days.

Yes, we provide free samples for most standard cables. You only need to cover the international courier costs. Contact us to arrange your sample shipment.

inquiry@qiangligroup.com +86 153 3220 6813