Factory-Direct Supply of Certified Wires and Conductors for Diverse Industrial Applications
RVMV & XRV Cable
Conductor: Copper, Class 1 solid or Class 2 stranded
Insulation: XLPE, rated 90°C
Armour: Steel wire armour (SWA), galvanized
Sheath: PVC Type ST2, black
Voltage: 600/1000V (0.6/1kV)
Number of cores: 2-5 cores per UNE 21123-2
Package: Heavy-duty wooden drum
Product Overview
RVMV & XRV Cable is a 0.6/1kV XLPE-insulated steel wire armoured (SWA) PVC-sheathed power cable manufactured to the Spanish standard UNE 21123-2. Two designations describe the same cable family: RVMV (R = steel wire armour, VMV = XLPE/PVC construction) and XRV (X = XLPE insulation, R = steel wire armour, V = PVC sheath). The dual naming reflects usage across Spanish-speaking and export markets where either designation may appear in project specifications. Single-core variants substitute aluminium wires for steel to eliminate eddy current heating — a requirement clearly stated in UNE 21123-2 for single-core SWA cables. For multi-core configurations, galvanized steel wires are standard since the magnetic fields of balanced phases cancel.
RVMV & XRV vs N2XRY: Spanish UNE vs British BS SWA
| Property | RVMV & XRV | N2XRY |
|---|---|---|
| Standard | UNE 21123-2 (Spanish) | BS 5467 / BS 6346 (British) |
| Construction | Cu / XLPE / SWA / PVC — identical | Cu / XLPE / SWA / PVC — identical |
| Test Voltage | 3.5 kV AC | 3.5 kV AC |
| Temperature Range | -15°C to +90°C | -40°C to +90°C |
| Single-Core Armour | Aluminium wires per UNE 21123-2 | Aluminium wires per BS 5467 |
| Primary Markets | Spain, Latin America, Spanish-influenced projects | UK, Commonwealth, global projects |
Cable Construction

1. Conductor — Copper, Class 1 solid or Class 2 stranded
2. XLPE Insulation — 90°C rated
3. Filler & Wrapping — Non-hygroscopic core assembly
4. PVC Bedding / Inner Sheath — Protects insulation from wire abrasion
5. Steel Wire Armour (R) — Galvanized wires, helical wound
6. PVC Outer Sheath — Type ST2, black
Copper Conductor
Soft annealed copper. Solid (Class 1) or rigid stranded (Class 2). Circular or sector-shaped for compact multi-core.
XLPE Insulation
Cross-linked polyethylene per UNE 21123-2. 90°C continuous, 250°C short-circuit (max 5s).
PVC Bedding (Inner Sheath)
Extruded PVC layer. Separates insulated cores from wire armour. Prevents wire abrasion during installation and service.
Steel Wire Armour (R)
Galvanized steel wires helically wound. Single-core: aluminium wires (marked LR in Spanish notation to indicate non-magnetic).
PVC Outer Sheath
PVC compound Type ST2 per IEC 60502-1. Black. Provides final mechanical and environmental protection.
Installation Versatility
Direct burial, free air, ducts. Excellent rodent resistance. 10×D bend radius. -15°C to +90°C operating range.
Insulation Color Coding (HD 308 S2)
| Number of Cores | With Earth | Without Earth |
|---|---|---|
| 2 | — | Blue — Brown |
| 3 | GN/YE — Blue — Brown | Brown — Black — Grey |
| 4 | GN/YE — Brown — Black — Grey | Blue — Brown — Black — Grey |
| 5 | GN/YE — Blue — Brown — Black — Grey | Blue — Brown — Black — Grey — Black |
Technical Characteristics
| Rated Voltage | 600/1000V (0.6/1kV) |
| Test Voltage | 3.5 kV AC, 5 minutes |
| Max. Conductor Temperature | 90°C (continuous), 250°C (short-circuit) |
| Operating Temperature Range | -15°C to +90°C |
| Min. Bending Radius | 10 × D |
| Min. Insulation Resistance | 20 MΩ × km |
| Flame Retardant | IEC 60332-1, EN 60332-1 |
Applicable Standards
| Standard | Scope |
|---|---|
| UNE 21123-2 | Spanish national standard for XLPE insulated, steel wire armoured power cables 0.6/1kV. Primary standard for RVMV & XRV. |
| IEC 60502-1 | International standard for power cables 1kV-30kV. All UNE 21123-2 cables meet IEC 60502-1 structural requirements. |
| IEC 60332-1 / EN 60332-1 | Flame non-propagation — single cable vertical flame test. |
| IEC 60332-3 / EN 50266 | Bundled cable flame propagation test. Higher fire safety tier than single-cable tests alone. |
| HD 308 S2 | Core identification color coding standard for CENELEC countries. |
Technical Specifications
Dimensional and electrical data per UNE 21123-2. Single-core cables use aluminium wire armour (LR designation). Multi-core (2-5 cores) use galvanized steel wire armour.
| Cross Section (mm²) | Insul. (mm) | Inner Sheath (mm) | Armour Wire Dia. (mm) | Outer Sheath (mm) | Outer Dia. (mm) | Weight (kg/km) |
|---|---|---|---|---|---|---|
| 2-Core | ||||||
| 2 × 4 | 0.7 | 0.8 | 0.9 | 1.8 | 15.4 | 327 |
| 2 × 6 | 0.7 | 0.8 | 0.9 | 1.8 | 16.4 | 399 |
| 2 × 10 | 0.7 | 0.8 | 0.9 | 1.8 | 18.4 | 472 |
| 2 × 16 | 0.7 | 0.8 | 1.25 | 1.8 | 20.8 | 762 |
| 2 × 25 | 0.9 | 1.0 | 1.25 | 1.8 | 24.2 | 921 |
| 2 × 35 | 0.9 | 1.0 | 1.25 | 1.8 | 25.8 | 1,208 |
| 2 × 50 | 1.0 | 1.0 | 1.6 | 1.8 | 29.2 | 1,589 |
| 2 × 70 | 1.1 | 1.2 | 1.6 | 1.8 | 32.8 | 2,126 |
| 2 × 95 | 1.1 | 1.2 | 1.6 | 1.9 | 36.6 | 2,698 |
| 2 × 120 | 1.2 | 1.2 | 2.0 | 2.0 | 40.6 | 3,409 |
| 2 × 150 | 1.4 | 1.4 | 2.0 | 2.1 | 45.0 | 3,361 |
| 2 × 185 | 1.6 | 1.4 | 2.0 | 2.2 | 49.4 | 4,249 |
| 2 × 240 | 1.7 | 1.6 | 2.5 | 2.4 | 56.0 | 7,556 |
| 3-Core | ||||||
| 3 × 4 | 0.7 | 0.8 | 0.9 | 1.8 | 15.8 | 373 |
| 3 × 6 | 0.7 | 0.8 | 0.9 | 1.8 | 17.2 | 475 |
| 3 × 10 | 0.7 | 0.8 | 0.9 | 1.8 | 19.2 | 574 |
| 3 × 16 | 0.7 | 0.8 | 1.25 | 1.8 | 22.4 | 953 |
| 3 × 25 | 0.9 | 1.0 | 1.25 | 1.8 | 26.2 | 1,208 |
| 3 × 35 | 0.9 | 1.0 | 1.25 | 1.8 | 28.0 | 1,558 |
| 3 × 50 | 1.0 | 1.0 | 1.6 | 1.9 | 32.0 | 2,227 |
| 3 × 70 | 1.1 | 1.2 | 1.6 | 1.9 | 36.0 | 3,064 |
| 3 × 95 | 1.1 | 1.2 | 1.6 | 2.0 | 39.8 | 3,078 |
| 3 × 120 | 1.2 | 1.2 | 2.0 | 2.1 | 44.2 | 4,300 |
| 3 × 150 | 1.4 | 1.4 | 2.0 | 2.2 | 49.2 | 4,666 |
| 3 × 185 | 1.6 | 1.4 | 2.0 | 2.3 | 53.4 | 4,856 |
| 3 × 240 | 1.7 | 1.6 | 2.5 | 2.5 | 60.8 | 8,831 |
| 4-Core | ||||||
| 4 × 4 | 0.7 | 0.8 | 0.9 | 1.8 | 16.6 | 434 |
| 4 × 6 | 0.7 | 0.8 | 0.9 | 1.8 | 18.0 | 550 |
| 4 × 10 | 0.7 | 0.8 | 0.9 | 1.8 | 20.4 | 674 |
| 4 × 16 | 0.7 | 0.8 | 1.25 | 1.8 | 24.4 | 1,136 |
| 4 × 25 | 0.9 | 1.0 | 1.25 | 1.8 | 28.4 | 1,453 |
| 4 × 35 | 0.9 | 1.0 | 1.6 | 1.9 | 31.2 | 2,034 |
| 4 × 50 | 1.0 | 1.2 | 1.6 | 2.0 | 35.8 | 3,055 |
| 4 × 70 | 1.1 | 1.2 | 1.6 | 2.1 | 39.6 | 3,123 |
| 4 × 95 | 1.1 | 1.4 | 2.0 | 2.2 | 45.6 | 4,786 |
| 4 × 120 | 1.2 | 1.4 | 2.0 | 2.3 | 49.8 | 5,036 |
| 4 × 150 | 1.4 | 1.6 | 2.0 | 2.5 | 55.4 | 5,976 |
| 4 × 185 | 1.6 | 1.6 | 2.5 | 2.6 | 61.2 | 8,674 |
| 4 × 240 | 1.7 | 1.8 | 2.5 | 2.8 | 68.2 | 10,808 |
| 5-Core | ||||||
| 5 × 4 | 0.7 | 0.8 | 0.9 | 1.8 | 17.6 | 501 |
| 5 × 6 | 0.7 | 0.8 | 0.9 | 1.8 | 19.0 | 632 |
| 5 × 10 | 0.7 | 0.8 | 1.25 | 1.8 | 22.6 | 946 |
| 5 × 16 | 0.7 | 0.8 | 1.25 | 1.8 | 25.6 | 1,254 |
| 5 × 25 | 0.9 | 1.0 | 1.25 | 1.8 | 30.0 | 1,750 |
| 5 × 35 | 0.9 | 1.0 | 1.6 | 2.0 | 34.4 | 2,497 |
| 5 × 50 | 1.0 | 1.2 | 1.6 | 2.1 | 38.8 | 3,924 |
Packaging & Delivery
Heavy-Duty Wooden Drum
Iron-reinforced drums required for SWA cables. Steel wire armour adds significant weight — drums must be rated accordingly.
Export Wooden Drum
Fumigated solid wood. Standard for international shipping. Steel-reinforced flanges for 95mm²+.
UNE-Compliant Marking
UNE 21123-2 compliant drum labeling, sequential meter marking. Spanish-standard packaging documentation.
Typical Applications
Direct Burial & Underground
SWA provides superior mechanical protection for buried installations. Excellent rodent resistance for underground networks.
Industrial Installations
Power supply in factories where cables face mechanical aggression during installation and service life.
Outdoor Fixed Installations
Free air, ducts, or direct burial. SWA protects against environmental mechanical aggression.
Spanish & Latin American Markets
UNE 21123-2 is the governing standard for SWA power cables in Spain and Spanish-influenced project specifications.
Power Distribution Networks
LV distribution where steel wire armour is specified for longitudinal pulling strength through ducts.
Building Infrastructure
Main feeders and vertical risers in multi-story buildings. SWA supports cable weight in vertical runs.
Request a Quote
Frequently Asked Questions
As a factory, we offer flexible MOQ depending on the cable type. For standard stock items, MOQ is low; for customized specifications, please contact our sales team for a detailed quote.
Yes, Qiangli cables are manufactured in compliance with international standards such as UL, CE, TUV, and VDE. We provide full test reports and certificates upon request.
Absolutely. We have a dedicated R&D team that can customize cable structure, material, color, and printing to meet your specific project needs.
For standard products, lead time is usually 7-15 days. For large-scale project orders or customized products, it typically ranges from 20 to 30 days.
Yes, we provide free samples for most standard cables. You only need to cover the international courier costs. Contact us to arrange your sample shipment.