Factory-Direct Supply of Certified Wires and Conductors for Diverse Industrial Applications
Duplex Cable Aluminum Conductor Overhead Service Drop Cable Wire 600V
Voltage: 600V (phase-to-phase or less)
Phase Conductor: 1350-H19 Al, solid or stranded, XLPE/PE insulated
Insulation: XLPE (UV-resistant), 1.14mm or 1.52mm (45/60 mils)
Neutral Messenger: Bare AAC/AAAC/ACSR (solid or stranded)
Application: Overhead residential & commercial service drops
Ampacity: 78-182A (6 AWG to 1/0 AWG)
Package: Export wooden reel or coil
Product Overview
Duplex Cable Aluminum Conductor Overhead Service Drop 600V is a neutral-supported overhead service drop cable in duplex (two-conductor) configuration. Phase conductor: concentrically stranded 1350-H19 aluminum, insulated with UV-resistant black XLPE or PE. Neutral messenger: bare conductor that serves double duty — carrying return current AND supporting the cable's entire mechanical span load between the utility pole and the building attachment point. Available with three neutral messenger types to suit different span length and strength requirements: AAC (all-aluminum, 1350-H19), AAAC (6201-T81 alloy, ~80% stronger), and ACSR (steel-reinforced, ~110% stronger than AAC).
Neutral Messenger Selection: AAC vs AAAC vs ACSR
| Messenger Type | Material | Strength vs AAC | Corrosion | Best For |
|---|---|---|---|---|
| AAC | 1350-H19 Al | Reference (100%) | Good | Short spans, coastal areas |
| AAAC | 6201-T81 Al alloy | ~80% stronger | Excellent | Medium-long spans, all environments |
| ACSR | 1350-H19 Al + steel core | ~110% stronger | Good (galvanized steel) | Longest spans, heavy ice/wind |
Cable Construction

1. Phase Conductor — Stranded compacted circular aluminium
2. Insulation — XLPE (UV-resistant)
3. Messenger Conductor — AAC / AAAC / ACSR
Applicable Standards
| Standard | Scope |
|---|---|
| ASTM B-230 | 1350-H19 aluminum wire for electrical purposes. Governs AAC phase and neutral conductor properties. |
| ASTM B-231 | Concentric-lay-stranded aluminum conductors (AAC). Governs stranding of phase and AAC neutral. |
| ASTM B-232 | ACSR conductor specification. Governs steel-reinforced neutral messenger construction. |
| ASTM B-399 | 6201-T81 aluminum alloy conductors (AAAC). Governs alloy neutral messenger properties. |
| ICEA S-76-474 | Neutral-supported power cable assemblies rated 600V. The primary standard for duplex service drop cable. |
Technical Specifications — Aluminum Duplex Service Drop 600V
Phase: 1350-H19 Al, solid or 7/19-strand. Insulation: 1.14mm (45 mils) or 1.52mm (60 mils) XLPE/PE. Messenger: AAC/AAAC/ACSR, solid or stranded. Weight: complete cable (phase + neutral + insulation). Ampacity: 75°C PE or 90°C XLPE, 40°C ambient.
| Code Name | Phase Size x Str | Insul. (mm) | Phase O.D. (mm) | Neutral Size x Str | Neutral Rating (kg) | Weight (kg/km) | Amp. (A) |
|---|---|---|---|---|---|---|---|
| AAC Bare Neutral (1350-H19 Messenger) | |||||||
| Pekingese | 6-Solid | 1.14 | 6.4 | 6-7 | 255 | 20.8 | 78 |
| Collie | 6-7 | 1.14 | 6.9 | 6-7 | 255 | 23.8 | 78 |
| Cocker | 6-7 | 1.52 | 7.7 | 6-7 | 255 | 32.7 | 78 |
| Dachshund | 4-Solid | 1.14 | 7.5 | 6-7 | 400 | 26.8 | 103 |
| Spaniel | 4-7 | 1.14 | 8.2 | 6-7 | 400 | 29.8 | 103 |
| Cairn | 4-7 | 1.52 | 8.9 | 6-7 | 400 | 40.2 | 103 |
| Doberman | 2-7 | 1.14 | 9.7 | 2-7 | 612 | 38.7 | 136 |
| Airedale | 1-19 | 1.52 | 11.5 | 1-7 | — | 56.5 | 158 |
| Basset | 1/0-7 | 1.52 | 12.4 | 1/0-7 | 903 | 64.0 | 182 |
| Malemure | 1/0-19 | 1.52 | 12.5 | 1/0-7 | 903 | 64.0 | 182 |
| AAAC Bare Neutral (6201-T81 Alloy Messenger) | |||||||
| Chihuahua | 6-Solid | 1.14 | 6.4 | 6-7 | 499 | 20.8 | 78 |
| Vizsla | 6-7 | 1.14 | 6.9 | 6-7 | 499 | 23.8 | 78 |
| Harrier | 4-Solid | 1.14 | 7.5 | 4-7 | 798 | 26.8 | 103 |
| Whippet | 4-7 | 1.14 | 8.2 | 4-7 | 798 | 29.8 | 103 |
| Schnauzer | 2-7 | 1.14 | 9.7 | 2-7 | 1270 | 38.7 | 136 |
| Afghan | 1/0-7 | 1.52 | 12.4 | 1/0-7 | 2023 | 64.0 | 182 |
| Heeler | 1/0-19 | 1.52 | 12.5 | 1/0-7 | 2023 | 64.0 | 182 |
| ACSR Bare Neutral (Steel-Reinforced Messenger) | |||||||
| Setter | 6-Solid | 1.14 | 6.4 | 6/6/01 ACSR | 540 | 20.8 | 78 |
| Shepherd | 6-7 | 1.14 | 6.9 | 6/6/01 ACSR | 540 | 23.8 | 78 |
| Retriever | 6-7 | 1.52 | 7.7 | 6/6/01 ACSR | 540 | 32.7 | 78 |
| Eskimo | 4-Solid | 1.14 | 7.5 | 4/6/01 ACSR | 844 | 26.8 | 103 |
| Terrier | 4-7 | 1.14 | 8.2 | 4/6/01 ACSR | 844 | 29.8 | 103 |
| Yorkshirc | 4-7 | 1.52 | 8.9 | 4/6/01 ACSR | 844 | 40.2 | 103 |
| Chow | 2-7 | 1.14 | 9.7 | 2/6/01 ACSR | 1293 | 38.7 | 136 |
| Labrador | 1-19 | 1.52 | 11.5 | 2/6/01 ACSR | 1610 | 56.5 | 158 |
| Bloodhound | 1/0-7 | 1.52 | 12.4 | 1/0-6/01 ACSR | 1987 | 64.0 | 182 |
| Bull | 1/0-19 | 1.52 | 12.5 | 1/0-6/01 ACSR | 1987 | 64.0 | 182 |
Packaging & Delivery
Export Wooden Reel
Plywood or wooden reels. Duplex cable is lightweight — compact reels suitable for utility line crew trucks.
Coil Packaging
Smaller AWG sizes available in coils. Utility-standard packaging for pole-top installation from service vehicles.
Documentation
ASTM B-230/B-231/B-232/B-399 mill certificates, neutral messenger tensile test, insulation thickness per ICEA S-76-474.
Typical Applications — Aluminum Duplex Service Drop
Residential Service Drops
Primary application. 120/240V single-phase overhead service from pole transformer to residential meter. Aluminum is the dominant conductor for utility service drops.
Lighting & Signage
Overhead connections to street lights, parking lot floodlights, illuminated signage, and billboard lighting installations.
Temporary Construction Power
Quick-deploy overhead service to construction trailers. ACSR neutral variant for longer-than-standard site service drops.
Outbuilding Connections
Service drops to detached garages, workshops, barns, and pump houses on the same property as the main residence.
Rural & Long-Span Drops
Longer rural service drops where pole-to-structure distance exceeds standard 30m. ACSR or AAAC neutral for extended spans.
Service Upgrades
Replacing undersized or weathered existing service drops during electrical service upgrades. Higher ampacity with same footprint.
Request a Quote
Frequently Asked Questions
As a factory, we offer flexible MOQ depending on the cable type. For standard stock items, MOQ is low; for customized specifications, please contact our sales team for a detailed quote.
Yes, Qiangli cables are manufactured in compliance with international standards such as UL, CE, TUV, and VDE. We provide full test reports and certificates upon request.
Absolutely. We have a dedicated R&D team that can customize cable structure, material, color, and printing to meet your specific project needs.
For standard products, lead time is usually 7-15 days. For large-scale project orders or customized products, it typically ranges from 20 to 30 days.
Yes, we provide free samples for most standard cables. You only need to cover the international courier costs. Contact us to arrange your sample shipment.