Factory-Direct Supply of Certified Wires and Conductors for Diverse Industrial Applications
LXRV Cable
Conductor: Aluminium, Class 2, circular or sector shaped
Insulation: XLPE, 90°C continuous, 250°C short-circuit
Armour: Galvanized steel wire (R); Al wire (IR) for single-core
Sheath: Black PVC type ST 2, flame retardant
Temperature: -15°C to +90°C, bending radius 10×D
Standard: UNE 21123-2, IEC 60502-1, IEC 60332-1/3
Product Overview
LXRV Cable is a 0.6/1kV XLPE-insulated steel wire armoured PVC-sheathed power cable with aluminium conductor, manufactured to the Spanish national standard UNE 21123-2 and international standard IEC 60502-1. Naming follows Spanish UNE convention: L = aluminium conductor (aluminio), X = XLPE insulation (polietileno reticulado), R = round steel wire armour (armadura de alambres de acero), V = PVC outer sheath. For single-core AC circuits, steel armour wires are substituted by aluminium wires (designated IR) to prevent eddy current heating. LXRV is the standard Spanish SWA cable for outdoor fixed installations requiring mechanical protection against aggression, rodents, and direct burial. Available with both circular stranded and sector-shaped conductors, the latter offering a more compact cable diameter for the same cross-section.

PVC Jacket — Black PVC type ST 2, UV resistant
Steel Wire Armour — Galvanized wires, helical applied
PVC Bedding — Extruded separation sheath
XLPE Insulation — 90°C, HD 308 S2 colour coded
Aluminium Conductor — Class 2, circular or sector shaped
Aluminium Conductor
Class 2 stranded per IEC 60228. Available in circular (standard) and sector-shaped (compact) configurations. Sector-shaped reduces overall cable diameter.
XLPE Insulation
90°C continuous, 250°C short-circuit (max 5s). Test voltage 3.5kV AC (5 minutes). Insulation resistance ≥20 MΩ×km.
PVC Bedding
Extruded PVC separation sheath. Protects XLPE insulation from steel wire abrasion during bending and thermal cycling.
Steel Wire Armour
Galvanized steel wires, helical applied. Substituted by aluminium wires (IR) for single-core AC circuits to prevent eddy current losses.
PVC Jacket (ST 2)
Black PVC type ST 2 per UNE 21123-2. Flame retardant (IEC 60332-1). High resistance to UV, moisture, and mechanical abrasion.
Circular vs Sector
Left: standard stranded circular. Right: sector-shaped — compact diameter, less bedding material, lighter weight per ampacity. Both available across the range.
Technical Characteristics
| Rated Voltage | 600/1000V (0.6/1kV) |
| Test Voltage | 3.5 kV AC — 5 minutes |
| Max. Conductor Temperature | 90°C (continuous), 250°C (short-circuit) |
| Working Temperature Range | -15°C to +90°C |
| Min. Bending Radius | 10 × overall diameter |
| Insulation Resistance | ≥ 20 MΩ × km |
| Flame Retardant | IEC 60332-1 (single cable), EN 50266 (bundled cables) |
| Armour Type | Galvanized steel wire (R); aluminium wire (IR) for single-core |
Applicable Standards
| Standard | Scope |
|---|---|
| UNE 21123-2 | Spanish national standard for XLPE insulated power cables 0.6/1kV. Primary standard covering LXRV construction, testing, and installation requirements. |
| IEC 60502-1 | International standard for LV extruded insulation power cables. LXRV meets all IEC 60502-1 structural and electrical requirements. |
| IEC 60332-1 | Single cable vertical flame test — flame non-propagation. |
| IEC 60332-3 / EN 50266 | Bundled cable flame test (Category C). Required for cables installed in groups in building risers and cable trays. |
| HD 308 S2 | Harmonised European core identification standard. Applied for consistent colour coding across EU markets. |
Core Identification (HD 308 S2)
| Config | With Earth (G) | Without Earth (x) |
|---|---|---|
| 2-Core | — | Blue + Brown |
| 3-Core | Green/Yellow + Blue + Brown | Brown + Black + Grey |
| 4-Core | Green/Yellow + Brown + Black + Grey | Blue + Brown + Black + Grey |
| 5-Core | Green/Yellow + Blue + Brown + Black + Grey | Blue + Brown + Black + Grey + Black |
Technical Data
Detailed dimensional and weight specifications vary by conductor cross-section, core count, and conductor shape (circular vs sector). The table below summarises the construction layers for reference. Request a complete quote with your required cross-section and core configuration for exact O.D., weight, and ampacity values.
Construction Reference by Core Configuration
| Core Configuration | Conductor Form | Insulation | Bedding | Armour | Sheath |
|---|---|---|---|---|---|
| 1 x (Single-Core) | Circular stranded | XLPE | PVC | Aluminium wires (IR) | PVC ST 2 |
| 2 x | Circular stranded | XLPE | PVC | Steel wires (R) | PVC ST 2 |
| 3 G / 3 x | Circular or sector | XLPE | PVC | Steel wires (R) | PVC ST 2 |
| 4 G / 4 x | Circular or sector | XLPE | PVC | Steel wires (R) | PVC ST 2 |
| 5 G / 5 x | Circular or sector | XLPE | PVC | Steel wires (R) | PVC ST 2 |
Conductor Shape Comparison
| Feature | Circular Stranded | Sector-Shaped |
|---|---|---|
| Cross-Section | Round (7+ strands) | Pie-slice (trapezoidal) |
| Cable Diameter | Standard (larger) | ~15% smaller |
| Weight per km | Standard | ~10% less (less bedding/filler) |
| Bending Flexibility | Uniform in all directions | Slightly directional |
| Typical Use | General purpose, small sizes | Large cross-sections, space-constrained |
| Available Core Counts | 1–5 cores | 3–5 cores (≥25mm²) |
Packaging & Delivery
| Parameter | Standard |
|---|---|
| Drum Type | Wooden drum / iron-wooden drum (SWA requires reinforced drums for heavy cable) |
| Length per Drum | 500m / 1000m (standard); custom lengths available |
| Drum Marking | Manufacturer, LXRV, voltage, cross-section, core config, length, weight, drum number, UNE mark |
| Cable End Sealing | Heat-shrink end caps with desiccant to prevent moisture ingress |
| Outer Protection | Weatherproof wrapping for sea freight; wooden pallet base for drum stability |
| Delivery Condition | Factory-new, tested per UNE 21123-2, with test certificate on request |
Typical Applications
Outdoor Fixed Installation
Designed for outdoor environments where mechanical aggression or rodent threat requires armoured protection. Direct burial, ducts, or free air.
Underground Distribution
Direct burial in soil for LV power distribution. SWA provides superior mechanical protection during laying, installation, and service life.
Industrial Networks
Power supply to factories and production facilities. 10×D bending radius allows routing through conduits and tight spaces.
Spanish & LATAM Markets
UNE 21123-2 certified for Spain and Latin American countries where UNE standards are adopted or referenced in local regulations.
Renewable Energy
LV collection in solar farms where aluminium conductor economics and SWA mechanical protection are required for field installation.
Infrastructure
Water treatment plants, pumping stations, and transport infrastructure requiring UNE-certified armoured power cable.
Request a Quote
Frequently Asked Questions
As a factory, we offer flexible MOQ depending on the cable type. For standard stock items, MOQ is low; for customized specifications, please contact our sales team for a detailed quote.
Yes, Qiangli cables are manufactured in compliance with international standards such as UL, CE, TUV, and VDE. We provide full test reports and certificates upon request.
Absolutely. We have a dedicated R&D team that can customize cable structure, material, color, and printing to meet your specific project needs.
For standard products, lead time is usually 7-15 days. For large-scale project orders or customized products, it typically ranges from 20 to 30 days.
Yes, we provide free samples for most standard cables. You only need to cover the international courier costs. Contact us to arrange your sample shipment.