Conductor Twin 16mm2 AAC PVC Parallel Aluminum Cable
Conductor: Hard drawn aluminium, 7/1.70mm, 16mm², Ø5.1mm
Insulation: Weather-resistant black PVC, ≥1.0mm avg (0.8mm min)
Construction: 2-core parallel twin, flat 4.0 × 15.5mm
DC Resistance: 1.813 Ω/km at 20°C
Breaking Strength: 2.827 kN per core
Standard: BS 6485, IEC 61089, IEC 61059
Product Overview
Conductor Twin 16mm² AAC PVC Parallel Aluminum Cable is a 0.6/1kV aerial bundled service drop cable with two parallel aluminium conductors, PVC insulated and weather-resistant. Designed to supply power from a pole-mounted transformer to the user's service head where connection to the service entrance is made. Rated for use at 600V or less phase-to-phase and at conductor temperatures not exceeding 75°C. Each core is identified by ribs on the insulation surface for easy phase identification during installation. Manufactured to BS 6485 and IEC 61089/61059 standards, this cable is the standard LV service drop solution for overhead distribution networks in residential, commercial, and rural electrification projects.
AAC Conductor
Hard drawn aluminium, stranded circular (RM). 7 strands × 1.70mm, cross-section 16mm². Conductor diameter 5.1mm per core.
PVC Insulation
Weather-resistant black PVC. Average thickness ≥1.0mm, minimum 0.8mm at any point. 70°C max conductor temperature, 160°C short-circuit.
Parallel Twin Construction
Two cores laid parallel in a flat configuration. Overall dimensions 4.0 × 15.5mm. Ribs on insulation for core identification.
Service Drop Rated
Designed for pole-to-building LV service drops. ≤600V phase-to-phase operation. Lightweight at 150 kg/km for easy overhead stringing.
Technical Characteristics
| Rated Voltage | 0.6/1kV (phase-to-phase ≤600V for service drop) |
| Test Voltage | 4 kV eff / 50 Hz |
| Max. Conductor Temperature | 70°C (continuous), 160°C (short-circuit, max 5s) |
| Operating Temperature Range | -30°C to +70°C |
| Min. Laying Temperature | -5°C |
| Min. Bending Radius | 15 × cable diameter |
| Core Identification | Number and ribs on insulation surface |
| Applicable Standards | BS 6485, IEC 61089, IEC 61059 |
Technical Specifications
Conductor Data
| Parameter | Unit | Value |
|---|---|---|
| Cable Type | — | AAC/PVC Covered 2-Core 16mm² Parallel |
| Conductor Material | — | Hard drawn aluminium (AAC) |
| Conductor Shape | — | Stranded circular, compressed (RM) |
| Nominal Cross-Section | mm² | 16 |
| Number of Cores | — | 2 (twin parallel) |
| Wire Configuration | No./mm | 7 / 1.70 |
| Conductor Diameter | mm | 5.1 |
Insulation & Cable Dimensions
| Parameter | Unit | Value |
|---|---|---|
| Insulation Material | — | PVC (weather resistant) |
| Insulation Colour | — | Black |
| Average Insulation Thickness | mm | ≥ 1.0 |
| Minimum Insulation Thickness | mm | ≥ 0.8 |
| Overall Cable Dimensions | mm | 4.0 × 15.5 (flat parallel twin) |
| Core Identification | — | Number and ribs |
Electrical & Mechanical Properties
| Parameter | Unit | Value |
|---|---|---|
| Max. DC Resistance at 20°C | Ω/km | 1.813 |
| Per Core Breaking Strength | kN | 2.827 |
| Approximate Cable Weight | kg/km | 150 |
| Rated Voltage | kV | 0.6/1 |
| Service Drop Operating Voltage | V | ≤ 600 (phase-to-phase) |
| Country of Origin | — | China |
Packaging & Delivery
| Parameter | Standard |
|---|---|
| Drum Type | Export wooden drum / iron-wooden drum / as per customer requirement |
| Length per Drum | Standard lengths available; custom coil lengths on request |
| Drum Marking | Manufacturer, cable type, voltage, cross-section, length, weight, drum number, BS mark |
| Cable End Sealing | Heat-shrink end caps to prevent moisture ingress |
| Outer Protection | Weatherproof wrapping for sea freight |
| Delivery Condition | Factory-new, tested per BS 6485 / IEC 61089, with test certificate on request |
Typical Applications
LV Service Drop
Primary application: overhead connection from pole-mounted distribution transformer to the building service entrance head. Rated ≤600V phase-to-phase.
Residential Electrification
Single-phase service to residential properties. Twin parallel configuration provides one pull installation for both phase and neutral.
Rural Distribution
Rural electrification projects where lightweight AAC conductor and simple twin construction minimise installation cost and time.
Utility Networks
Standard service drop cable for power utility companies. BS 6485 / IEC 61089 certified for utility-grade overhead distribution.
Temporary Site Supply
Temporary power supply to construction sites and events where overhead routing from a nearest pole is required.
Street Lighting
Overhead power supply to street lighting circuits where parallel twin construction simplifies connection to luminaires.
Request a Quote
Frequently Asked Questions
As a factory, we offer flexible MOQ depending on the cable type. For standard stock items, MOQ is low; for customized specifications, please contact our sales team for a detailed quote.
Yes, Qiangli cables are manufactured in compliance with international standards such as UL, CE, TUV, and VDE. We provide full test reports and certificates upon request.
Absolutely. We have a dedicated R&D team that can customize cable structure, material, color, and printing to meet your specific project needs.
For standard products, lead time is usually 7-15 days. For large-scale project orders or customized products, it typically ranges from 20 to 30 days.
Yes, we provide free samples for most standard cables. You only need to cover the international courier costs. Contact us to arrange your sample shipment.