Factory-Direct Supply of Certified Wires and Conductors for Diverse Industrial Applications
U-1000 RVFV XAV HFG Cable
Conductor: Copper, Class 1 (≤4mm²) or Class 2 (≥6mm²)
Insulation: XLPE, rated 90°C
Armour: Double steel or aluminium tape
Sheath: PVC, black, low halogen (Cl<15%)
Voltage: 600/1000V (0.6/1kV)
Number of cores: 2-4 cores, 3+reduced per NF C 32-322
Package: Export wooden drum
Product Overview
U-1000 RVFV XAV Cable is a 0.6/1kV XLPE-insulated armored power cable manufactured to the French standard NF C 32-322. Naming: U-1000 = 1000V rating (French designation for 0.6/1kV), R = rigid conductor, V = XLPE insulation, FV = tape armor (steel or aluminium), XAV = indicating aluminium tape option for single-core. It is the French NFC equivalent of the Spanish UNE 21123 RVFV-K — both share identical construction principles: XLPE insulation, double steel or aluminium tape armor, PVC sheath, with aluminium tape mandatory for single-core to avoid eddy current heating. The conductor is Class 1 (solid, 1.5-4mm²) or Class 2 (stranded, 6mm²+), with Class 2 also available for smaller sizes on request.
NFC vs UNE: Two Standards, Same Cable
| Standard | Designation | Key Standard | Markets |
|---|---|---|---|
| French NFC | U-1000 RVFV XAV | NF C 32-322 | France, Francophone Africa, Maghreb |
| Spanish UNE | RVFV-K | UNE 21123 | Spain, Latin America |
| International IEC | IEC 60502-1 Armored XLPE/PVC | IEC 60502-1 | Global |
Cable Construction
Copper Conductor
Class 1 solid (1.5-4mm²) or Class 2 stranded (6mm²+). Class 2 available for smaller sizes on request.
XLPE Insulation
Cross-linked polyethylene per IEC 60502-1. 90°C continuous, 250°C short-circuit (max 5s).
PVC Bedding
Black extruded PVC separation sheath between laid-up cores and armor. Ensures smooth bedding surface.
Tape Armour (FV/XAV)
Double steel tape (multi-core) or aluminium tape (single-core mandatory per NFC). 0.2mm for ≤35mm², 0.5mm for ≥50mm².
PVC Outer Sheath
Flexible PVC, black. Low halogen (chlorine <15%), flame-retardant per NF C 32-070 C2.
Versatile Installation
5×D bend radius. -40°C to +90°C. Direct burial, conduit, open air. Meter-by-meter marking. CPR Eca.
Core Identification (NF C 32-322)
| Configuration | Core Colors |
|---|---|
| 1 x | Natural |
| 2 x | Blue + Brown |
| 3 G | Blue + Brown + Green/Yellow |
| 3 x | Brown + Black + Grey |
| 3 x + 1 x | Brown + Black + Grey + Blue (reduced) |
| 4 G | Brown + Black + Grey + Green/Yellow |
| 4 x | Brown + Black + Grey + Blue |
| 5 G | Brown + Black + Grey + Blue + Green/Yellow |
| 6 or more | Black numbered + Green/Yellow |
Technical Characteristics
| Rated Voltage | 600/1000V (0.6/1kV) |
| Max. Conductor Temperature | 90°C (continuous), 250°C (short-circuit) |
| Min. Service Temperature | -40°C (fixed and protected) |
| Min. Bending Radius | 5 × D |
| Fire Performance | Flame non-propagation IEC 60332-1, NF C 32-070 C2 |
| Halogen Content | Low halogen — chlorine <15% |
| CPR Class | Eca per EN 50575 |
| Impact Resistance | AG2 Medium severity |
Applicable Standards & Certifications
| Standard | Scope |
|---|---|
| NF C 32-322 | French national standard for XLPE insulated armored power cables 0.6/1kV. The primary standard for U-1000 RVFV. |
| NF C 32-070 C2 | French flame retardancy test — Category 2 bundled cable fire performance. More stringent than single-cable IEC 60332-1. |
| IEC 60502-1 | International standard for power cables 1kV-30kV. U-1000 RVFV meets all IEC 60502-1 requirements. |
| IEC 60332-1-2 | Flame non-propagation — single cable vertical flame test. |
| EN 50575 | CPR fire classification — Eca class. Mandatory for cables sold in EU since July 2017. |
| UNE 211605 | Spanish UV resistance certification — accepted for French outdoor installations. |
Technical Specifications — Dimensional Data
All values per NF C 32-322. Dimensions represent maximum values. Armor thickness: 0.2mm (≤35mm²), 0.5mm (≥50mm²). For current ratings and voltage drop data, refer to the RVFV-K specification which uses the same cable construction per IEC 60502-1.
| Cross Section (mm²) | Insulation (mm) | Armour (mm) | Min. Sheath (mm) | Max. Outer Dia. (mm) | Approx. Weight (kg/km) |
|---|---|---|---|---|---|
| 2-Core | |||||
| 2 × 1.5 | 0.7 | 0.2 | 1.3 | 11.5 | 230 |
| 2 × 2.5 | 0.7 | 0.2 | 1.3 | 12.5 | 275 |
| 2 × 4 | 0.7 | 0.2 | 1.4 | 13.5 | 330 |
| 2 × 6 | 0.7 | 0.2 | 1.4 | 15.5 | 430 |
| 2 × 10 | 0.7 | 0.2 | 1.4 | 16.5 | 555 |
| 2 × 16 | 0.7 | 0.2 | 1.5 | 19 | 770 |
| 2 × 25 | 0.9 | 0.2 | 1.6 | 22.5 | 1,080 |
| 2 × 35 | 0.9 | 0.2 | 1.7 | 25 | 1,390 |
| 3-Core | |||||
| 3 × 1.5 | 0.7 | 0.2 | 1.3 | 12 | 255 |
| 3 × 2.5 | 0.7 | 0.2 | 1.3 | 13 | 305 |
| 3 × 4 | 0.7 | 0.2 | 1.4 | 14 | 380 |
| 3 × 6 | 0.7 | 0.2 | 1.4 | 16 | 500 |
| 3 × 10 | 0.7 | 0.2 | 1.5 | 17.5 | 665 |
| 3 × 16 | 0.7 | 0.2 | 1.5 | 20 | 930 |
| 3 × 25 | 0.9 | 0.2 | 1.6 | 24 | 1,325 |
| 3 × 35 | 0.9 | 0.2 | 1.7 | 26.5 | 1,720 |
| 3 × 50 | 0.9 | 0.2 | 1.8 | 29 | 2,125 |
| 3 × 70 | 1.1 | 0.2 | 2.0 | 34.5 | 3,080 |
| 3 × 95 | 1.1 | 0.5 | 2.1 | 40 | 4,505 |
| 3 × 120 | 1.2 | 0.5 | 2.3 | 44.5 | 5,540 |
| 3 × 150 | 1.4 | 0.5 | 2.4 | 48.5 | 6,655 |
| 3 × 185 | 1.6 | 0.5 | 2.5 | 53.5 | 8,150 |
| 3 × 240 | 1.7 | 0.5 | 2.7 | 61 | 10,575 |
| 3 × 300 | 1.8 | 0.5 | 2.9 | 66.5 | 13,055 |
| 3-Core + Reduced Neutral | |||||
| 3 × 50 + 35 | 1.0/0.9 | 0.2 | 1.9 | 33 | 2,730 |
| 3 × 70 + 50 | 1.1/0.9 | 0.2 | 2.0 | 36 | 3,440 |
| 3 × 95 + 50 | 1.1/1.0 | 0.5 | 2.2 | 42.5 | 5,080 |
| 3 × 120 + 70 | 1.2/1.1 | 0.5 | 2.3 | 46.5 | 6,275 |
| 3 × 150 + 70 | 1.4/1.1 | 0.5 | 2.5 | 50 | 7,340 |
| 3 × 185 + 70 | 1.6/1.1 | 0.5 | 2.6 | 56 | 8,975 |
| 3 × 240 + 95 | 1.7/1.1 | 0.5 | 2.8 | 62.5 | 11,435 |
| 4-Core | |||||
| 4 × 1.5 | 0.7 | 0.2 | 1.3 | 13 | 290 |
| 4 × 2.5 | 0.7 | 0.2 | 1.4 | 14 | 355 |
| 4 × 4 | 0.7 | 0.2 | 1.4 | 15 | 440 |
| 4 × 6 | 0.7 | 0.2 | 1.4 | 17 | 585 |
| 4 × 10 | 0.7 | 0.2 | 1.5 | 19 | 800 |
| 4 × 16 | 0.7 | 0.2 | 1.6 | 22 | 1,120 |
| 4 × 25 | 0.9 | 0.2 | 1.7 | 26 | 1,650 |
| 4 × 35 | 0.9 | 0.2 | 1.8 | 29 | 2,135 |
| 4 × 50 | 1.0 | 0.2 | 1.9 | 32.5 | 2,745 |
| 4 × 70 | 1.1 | 0.5 | 2.1 | 39 | 4,295 |
| 4 × 95 | 1.1 | 0.5 | 2.3 | 44.5 | 5,660 |
| 4 × 120 | 1.2 | 0.5 | 2.4 | 48.5 | 6,880 |
| 4 × 150 | 1.4 | 0.5 | 2.6 | 53 | 8,315 |
| 4 × 185 | 1.6 | 0.5 | 2.7 | 60.5 | 10,510 |
| 4 × 240 | 1.7 | 0.5 | 2.9 | 67 | 13,370 |
| 4 × 300 | 1.8 | 0.5 | 3.1 | 73 | 16,360 |
Packaging & Delivery
Export Wooden Drum
Fumigated wooden drums. Standard for international sea freight and container loading.
Coil Packaging
Smaller cross-sections available in coils for cost-efficient short-haul transport and on-site handling.
Custom Packaging
NF C 32-322 compliant marking, custom drum labeling, sequential meter marking. MOQ applies.
Typical Applications
U-1000 RVFV is specified for projects governed by French NFC standards — Francophone Africa, Maghreb, and French-influenced markets:
Direct Burial
Underground LV distribution per NF C 32-322. Steel tape armor permits direct burial without additional mechanical protection.
Industrial Plants
Heavy industrial environments. C2-rated flame performance per NF C 32-070 for factories and processing plants.
French-Regulated Buildings
Public buildings, high-rises, and infrastructure in France and oversea territories. G-type cables mandated for safety circuits.
Francophone Africa
Infrastructure projects in West and Central Africa where NF C 32-322 certification is a tender requirement.
Substations & Switchyards
Inter-station connections. XLPE insulation handles elevated ambient temperatures in electrical yards.
Maghreb Markets
Algeria, Morocco, Tunisia infrastructure projects accepting French NFC certification as equivalent to local standards.
Request a Quote
Frequently Asked Questions
As a factory, we offer flexible MOQ depending on the cable type. For standard stock items, MOQ is low; for customized specifications, please contact our sales team for a detailed quote.
Yes, Qiangli cables are manufactured in compliance with international standards such as UL, CE, TUV, and VDE. We provide full test reports and certificates upon request.
Absolutely. We have a dedicated R&D team that can customize cable structure, material, color, and printing to meet your specific project needs.
For standard products, lead time is usually 7-15 days. For large-scale project orders or customized products, it typically ranges from 20 to 30 days.
Yes, we provide free samples for most standard cables. You only need to cover the international courier costs. Contact us to arrange your sample shipment.