Factory-Direct Supply of Certified Wires and Conductors for Diverse Industrial Applications

Building Wire
450/750V halogen free polyolefin insulated wire, flexible & rigid LSOH building cable comparison diagram

450/750V Halogen Free Polyolefine Insulated Wire HFIX

450/750V HFIX Halogen-Free Polyolefin Copper Wire — KS C 3341, LSOH, 90°C, 20 Colours

Voltage: 450/750V, test 2,500V/5min, LSOH zero halogen emission
Conductor: Annealed copper, Class 1 solid & Class 2 stranded (dual for 1.5-10mm²)
Insulation: Halogen-free polyolefin — 90°C, LOI ≥45% self-extinguishing, low smoke
Bending: 4 × D, 20 standard colours — widest palette in any building wire product
Range: 22 sizes 1.5-300mm², 20-2,830 kg/km, 300m rolls (200m/100m large sizes)
Fire Safety: Zero HCl/HF/HBr gas — CO₂ + H₂O only when burned vs toxic PVC smoke
Standard: KS C 3341, IEC 60754-1/2 compliant, Korean Fire Protection Code Art. 34

Product Overview

450/750V Halogen Free Polyolefine Insulated Wire HFIX is a single-core copper conductor wire with halogen-free polyolefin insulation manufactured to the Korean standard KS C 3341. HFIX = Halogen Free Insulated EXcellent — the LSOH (Low Smoke Zero Halogen) alternative to the standard PVC-insulated IV and KIV building wires. When burned, the polyolefin insulation emits no halogen acid gases (HCl, HF, HBr), produces significantly less smoke than PVC, and generates primarily carbon dioxide and water vapour — a critical safety advantage in enclosed public spaces, tunnels, hospitals, and high-occupancy buildings where toxic smoke from burning PVC cables is the primary cause of fire fatalities. The insulation is rated 90°C continuous — the same temperature class as heat-resistant PVC/E (HIV wire) but achieved without the chlorinated compound chemistry that creates halogen gases under fire conditions.

HFIX is the Korean domestic implementation of the global LSOH building wire standard — structurally equivalent to the European H07Z1-K/R (halogen-free polyolefin, 90°C, 450/750V) and the international IEC 60754-1/2 compliant halogen-free wire. The KS C 3341 standard mandates a minimum 1.45 limiting oxygen index (LOI) for the insulation — meaning the material requires at least 45% ambient oxygen to sustain combustion, compared to ~20% for PVC. In a real fire, the polyolefin insulation self-extinguishes when the external flame source is removed, while PVC continues to burn and release dense, toxic smoke. The trade-off for this safety improvement is a slightly larger overall diameter than PVC wire for the same conductor cross-section (polyolefin requires a marginally thicker insulation wall to achieve the same dielectric strength) and a higher per-metre cost — but for Korean public buildings, subways, and high-rise residential construction where LSOH wire has been mandatory since the early 2000s under the Korean Fire Protection Code, HFIX is not an option but a requirement.

The dual conductor class availability (Class 1 solid for screw terminals, Class 2 stranded for conduit pulls) mirrors the IV wire range, with 22 sizes from 1.5mm² to 300mm². The standout feature is the 20 standard insulation colours — black, white, red, green, yellow, blue, green-yellow, grey, brown, sky-blue, orange, pink, purple, ivory, dark-blue, dark-brown, transparent, light-green, dark-green, light-blue — a dramatically wider palette than the 6-colour Korean PVC standard, reflecting LSOH wire's use in complex control panels, instrumentation, and industrial machinery where multi-colour identification of dozens of circuits in a single enclosure is essential. All sizes are 300m standard rolls except 240mm² (200m) and 300mm² (100m).

HFIX Wire — Four-diagram cross section showing solid and stranded copper conductors with halogen-free polyolefin insulation

Top Row — Solid Conductor (Class 1):
Left: Longitudinal view — Conductor (solid copper rod) + Insulation (green halogen-free polyolefin jacket)
Right: Cross-section — single solid copper circle + green polyolefin ring

Bottom Row — Stranded Conductor (Class 2):
Left: Longitudinal view — Conductor (7-strand copper bundle) + Insulation (green halogen-free polyolefin jacket)
Right: Cross-section — seven copper circles in hexagonal packing + green polyolefin ring

1

Halogen-Free Polyolefin 90°C

Zero halogen acid gas emission when burned — CO₂ + H₂O only. LOI ≥45% — self-extinguishing. Same 90°C rating as heat-resistant PVC without chlorinated chemistry.

2

Low Smoke — High Visibility Escape

Smoke density ≤60% transmittance per KS C 3341. PVC emits 80-95% opacity smoke — LSOH preserves visibility for escape route navigation during fire evacuation.

3

Class 1 Solid & Class 2 Stranded

Both conductor types from 1.5-10mm² — solid for screw terminals, stranded for conduit pulls. Class 2 extends to 300mm² for heavy feeder wiring.

4

22 Sizes 1.5-300mm²

1.5mm² (20 kg/km) to 300mm² (2,830 kg/km). 300m rolls (≤185mm²), 200m (240mm²), 100m (300mm²). Export wooden case.

5

20 Standard Colours

Green-yellow earth, 7 phase colours, 12 auxiliary colours — the widest palette in any single building wire product. Multi-colour control panel and instrumentation wiring.

6

KS C 3341 — Korean LSOH Standard

Korean national standard for halogen-free polyolefin insulated wire. Equivalent to H07Z1-K/R (EU) and IEC 60754-1/2 compliant for zero halogen emission.

Technical Characteristics

Nominal Voltage Uo/U450/750V
Test Voltage2,500V AC
Max. Conductor Temperature+90°C (continuous, polyolefin insulation)
Temperature Range (in motion)+5°C to +90°C
Min. Bending Radius4 × outer diameter
Conductor ClassesClass 1 (solid) & Class 2 (stranded), annealed copper — KS C 3341
Insulator MaterialHalogen-free polyolefin — zero HCl/HF/HBr emission
StandardKS C 3341 (Korean halogen-free polyolefin wire standard)

Applicable Standards

StandardScope
KS C 3341Korean national standard for halogen-free polyolefin insulated wire — 450/750V, 90°C, low smoke zero halogen. Covers HFIX wire construction, testing, and fire performance including LOI, smoke density, and halogen acid gas emission limits.
IEC 60754-1/2International standard for halogen acid gas emission testing — HFIX insulation meets the zero halogen requirement for LSOH classification. Referenced globally for halogen-free cable compliance.

LSOH vs PVC — Fire Safety Comparison

PropertyHFIX (Polyolefin)IV/KIV (PVC)
Halogen Acid Gas EmissionZero (HCl, HF, HBr)HCl gas (from PVC decomposition)
Smoke Density≤60% opacity (low)80-95% opacity (dense black)
Limiting Oxygen Index≥45% (self-extinguishing)~20% (burns in air)
Operating Temperature90°C70°C
Insulation Wall ThicknessSlightly thicker (same CSA)Thinner (same CSA)
Cost Per MetreHigherLower

Technical Specifications

Annealed copper conductor per KS C 3341. Class 1 = solid wire. Class 2 = stranded wire. Halogen-free polyolefin insulator, 20 standard colours. DC resistance at 20°C. Test voltage 2,500V/5min. 22 sizes: Class 1 for 1.5-10mm², Class 2 for 1.5-300mm². Standard lengths 300m (≤185mm²), 200m (240mm²), 100m (300mm²).

Nominal Area
(mm²)
ClassConductor
(No. × mm)
Cond. OD
(mm)
Insulation
(mm)
Overall OD
(mm)
20°C Res.
(Ω/km)
Test
(V/min)
Weight
(kg/km)
Length
(m)
Class 1 Solid & Class 2 Stranded — Dual Availability (1.5-10mm²)
1.511 × 1.381.40.72.812.12,500/520300
1.527 × 0.531.60.73.012.12,500/520300
2.511 × 1.781.80.83.47.412,500/530300
2.527 × 0.672.00.83.67.412,500/535300
411 × 2.252.30.83.94.612,500/550300
427 × 0.852.60.84.24.612,500/555300
611 × 2.762.80.84.43.082,500/570300
627 × 1.043.10.84.73.082,500/575300
1011 × 3.573.61.05.61.832,500/5110300
1027 × 1.354.11.06.11.832,500/5120300
Class 2 Stranded Only (16-300mm²)
1627 × 1.705.11.07.11.152,500/5170300
2527 × 2.146.41.28.80.7272,500/5260300
3527 × 2.527.61.210.00.5242,500/5370300
50219 × 1.788.91.411.70.3872,500/5510300
70219 × 2.1410.71.413.50.2682,500/5690300
95219 × 2.5212.61.615.80.1932,500/5950300
120237 × 2.0314.21.617.40.1532,500/51,180300
150237 × 2.2515.81.819.40.1242,500/51,470300
185237 × 2.5217.62.021.60.09912,500/51,830300
240261 × 2.2420.22.224.60.07542,500/52,360200
300261 × 2.5022.52.427.30.06012,500/52,830100
Why LSOH polyolefin insulation costs more: The per-metre price premium of HFIX over IV/KIV wire reflects three cost drivers: (1) polyolefin compound is more expensive per kg than PVC compound, (2) the slightly thicker insulation wall (e.g. 0.7mm for 1.5mm² HFIX vs 0.7mm for PVC — similar at small sizes but the dielectric constant difference requires marginally more material for equivalent performance at larger sizes), and (3) manufacturing line changeover and dedicated tooling to prevent PVC cross-contamination of the LSOH compound. However, in Korean public building projects where fire safety regulations (Korean Fire Protection Code, Article 34) mandate LSOH wire for all enclosed spaces, the cost difference is non-negotiable — it is a compliance cost, not a discretionary upgrade.

Packaging & Delivery

ParameterStandard
Package300m/roll (≤185mm²), 200m/roll (240mm²), 100m/roll (300mm²), export wooden case & pallet
Roll MarkingManufacturer, HFIX, 450/750V, KS C 3341, cross-section, Class, LSOH, length, weight, batch, KS mark
Colour Options20 colours: black, white, red, green, yellow, blue, green-yellow, grey, brown, sky-blue, orange, pink, purple, ivory, dark-blue, dark-brown, transparent, light-green, dark-green, light-blue
Outer ProtectionWooden case — standardised across all LSOH product lines
Delivery ConditionFactory-new, tested per KS C 3341, halogen-free certified per IEC 60754-1/2, KS mark, test certificate on request

Typical Applications

HFIX halogen-free wire is mandated by fire safety codes for all enclosed public spaces in Korea — the wire that protects human life when a fire breaks out:

🏥

Hospitals & Healthcare

Zero toxic smoke emission — critical for patient evacuation where respiratory vulnerability makes PVC smoke fatal within minutes of exposure.

🚇

Subway & Tunnel Installations

Korean subway stations and tunnels mandate LSOH wire for all electrical systems — smoke in an underground enclosed space is the primary fatality risk.

🏢

High-Rise Residential

Mandatory in Korean apartment buildings per Fire Protection Code Article 34 — floor-to-floor wiring must be LSOH to prevent toxic smoke propagation through risers.

🎨

20-Colour Control Panels

Unique 20-colour palette enables individual circuit identification in complex industrial control panels — more than triple the standard 6-colour PVC range.

🇰🇷

Korean Public Buildings

KS C 3341 certified for all Korean public building electrical installations — compliance with Korean Fire Protection Code for LSOH wire.

🔥

Fire Escape Route Wiring

Low smoke density preserves visibility for escape route lighting circuits — the difference between finding the exit and being blinded by toxic PVC smoke.

Request a Quote

Ready to Work Together? Build a project with us!
This field is required.
This field is required.
Learn More From

Frequently Asked Questions

As a factory, we offer flexible MOQ depending on the cable type. For standard stock items, MOQ is low; for customized specifications, please contact our sales team for a detailed quote.

Yes, Qiangli cables are manufactured in compliance with international standards such as UL, CE, TUV, and VDE. We provide full test reports and certificates upon request.

Absolutely. We have a dedicated R&D team that can customize cable structure, material, color, and printing to meet your specific project needs.

For standard products, lead time is usually 7-15 days. For large-scale project orders or customized products, it typically ranges from 20 to 30 days.

Yes, we provide free samples for most standard cables. You only need to cover the international courier costs. Contact us to arrange your sample shipment.

inquiry@qiangligroup.com +86 153 3220 6813