Factory-Direct Supply of Certified Wires and Conductors for Diverse Industrial Applications

Power Cable

ACYY / ACYY-F Cable

Low voltage, 0.6/1 kV aluminium conductor PVC insulated and sheathed cable

Conductor: Aluminum, Class 1 (RE) or Class 2 (RM/SM)
Insulation: PVC compound DIV 1, rated 70°C
Sheath: PVC compound DMV 1, black
Voltage: 0.6/1 kV
Number of cores: 1, 4, 5 cores per HD 603 S1
Package: Export wooden drum

Product Overview

ACYY / ACYY-F Cable is a 0.6/1kV unarmored power cable with aluminum conductor, PVC insulation and PVC sheath. Designated for HD 603 S1/3G-2 and IEC 60502, it is the general-purpose European-standard aluminum power cable for applications where copper is not economically justified. The "F" variant (ACYY-F) designates a flat cable configuration for narrow ducts and confined installation spaces.

Aluminum Unarmored Cable Family Comparison

DesignationStandardConfigurationPrimary Market
ACYY / ACYY-FHD 603 S1/3G-2, IEC 605021C, 4C, 5CGeneral European
1-AYKYPNE 34 7659-33C, 4C, 5C, 3+1Poland / CEE
AVVGGOST 16442-801C-5C, 3+1Russia / CIS
NAYYDIN VDE 0276-6031C-5CGermany / DACH
1

Aluminum Conductor

Class 1 solid (RE) or Class 2 stranded (RM/SM). EN 60228. 61% IACS conductivity at ~50% weight vs copper.

2

PVC Insulation

Compound DIV 1 per HD 603 S1. 70°C continuous, 160°C short-circuit (max 5s).

3

PVC Bedding

Extruded elastomeric or plastomeric compound, or plastic tape. Applied over laid-up cores.

4

PVC Sheath

Compound DMV 1, black. Flame retardant EN 50265-2-1 / IEC 60332-1. Core ID per HD 308 S2.

Technical Characteristics

Rated Voltage0.6/1 kV
Test Voltage4 kV AC
Max. Conductor Temperature70°C (continuous), 160°C (short-circuit, max 5s)
Operating Temperature-50°C to +70°C
Min. Installation Temperature+5°C (without pre-heating)
Min. Bending Radius15 × D
Flame RetardantEN 50265-2-1, IEC 60332-1

Applicable Standards

StandardScope
HD 603 S1/3G-2CENELEC Harmonization Document — distribution cables of rated voltage 0.6/1kV. Covers multi-core PVC insulated, PVC sheathed unarmored cables.
IEC 60502International standard for extruded insulation power cables 1kV-30kV. ACYY meets all structural requirements.
EN 60228Conductor specification — Class 1 (RE, solid) and Class 2 (RM/SM, stranded) for aluminum conductors.
HD 308 S2Core identification color coding for CENELEC countries.
EN 50265-2-1 / IEC 60332-1Flame retardant test — single cable vertical flame propagation.
ACYY vs ACYY-F: ACYY is the standard round cable. ACYY-F is the flat variant — identical construction with cores laid side-by-side instead of circular bundling, providing reduced overall height for installation in narrow ducts, under-floor channels, and confined spaces where round cable outer diameter is limiting.

Technical Specifications

RE = solid round (Class 1). RM = round stranded (Class 2). SM = sector-shaped compacted stranded (Class 2). Resistance values use decimal point notation (reference source used European comma decimal — corrected throughout).

Cross Section
(mm²)
Conductor
Type
Max. Resistance
at 20°C (Ω/km)
Current
Air (A)
Current
Earth (A)
Outer Dia.
(mm)
1-Core
1 × 16RE1.919.5
1 × 25RE1.2010611411.0
1 × 35RM0.86813013612.1
1 × 50RM0.64116116213.6
1 × 70RM0.44320419915.2
1 × 95RM0.32025223816.8
1 × 120RM0.25329527218.4
1 × 150RM0.20633930520.2
1 × 185RM0.16439534722.1
1 × 240RM0.12547240424.5
1 × 300RM0.10054745726.7
4-Core
4 × 16RE1.9118.3
4 × 25SM1.2010211221.1
4 × 35SM0.86812613523.4
4 × 50SM0.64114915826.4
4 × 70SM0.44319119630.4
4 × 95SM0.32023423434.1
4 × 120SM0.25327326838.1
4 × 150SM0.20631130042.1
4 × 185SM0.16436034246.6
4 × 240SM0.12542739852.2
4 × 300SM0.10050745755.9
5-Core
5 × 10RE3.0817.8
5 × 16RE1.9120.0
5 × 25SM1.2010211222.9
5 × 35SM0.86812613525.7
5 × 50SM0.64114915830.1
5 × 70SM0.44319119635.1
5 × 95SM0.32023423438.1
5 × 120SM0.25327326840.3
5 × 150SM0.20631130047.4
5 × 185SM0.16436034252.7
5 × 240SM0.12542739859.4
Reference data corrections: Source listed 1×300mm² resistance as "1.80 Ω/km" — an obvious entry error (300mm² aluminum resistance is ~0.10 Ω/km, not 1.80). Corrected to 0.100 Ω/km per EN 60228 Class 2 aluminum conductor standard values. All European comma-decimal notation converted to decimal point.

Packaging & Delivery

🪵

Export Wooden Drum

Fumigated wooden drums. Aluminum cable lighter than copper — compact drums for cost-efficient shipping.

📦

Coil Packaging

Smaller cross-sections (≤70mm²) available in coils. ACYY-F flat variant coils for narrow duct installations.

📋

Custom Packaging

HD 603-compliant drum labeling, sequential meter marking. Customer-specified drum types on request.

Typical Applications

Power Station Supply

Primary application — power supply circuits to generating stations. Fixed indoor and outdoor installations.

🏗️

Underground in Pipes

Cable pipes, ducts, and concrete embedment. Not for direct burial without conduit — no mechanical protection.

🏭

Industrial & Sewers

Open and confined area installations. Suitable for sewer environments where no mechanical damage is expected.

🔲

Narrow Ducts (ACYY-F)

Flat ACYY-F variant for under-floor channels, narrow cable trays, and confined routing paths.

🌍

European Markets

HD 603 S1/3G-2 certified. General European standard — accepted across EU/EEA member states.

❄️

Cold Climate

-50°C minimum operating temperature. Suitable for outdoor installations in continental European winter.

Request a Quote

Ready to Work Together? Build a project with us!
This field is required.
This field is required.
Learn More From

Frequently Asked Questions

As a factory, we offer flexible MOQ depending on the cable type. For standard stock items, MOQ is low; for customized specifications, please contact our sales team for a detailed quote.

Yes, Qiangli cables are manufactured in compliance with international standards such as UL, CE, TUV, and VDE. We provide full test reports and certificates upon request.

Absolutely. We have a dedicated R&D team that can customize cable structure, material, color, and printing to meet your specific project needs.

For standard products, lead time is usually 7-15 days. For large-scale project orders or customized products, it typically ranges from 20 to 30 days.

Yes, we provide free samples for most standard cables. You only need to cover the international courier costs. Contact us to arrange your sample shipment.

inquiry@qiangligroup.com +86 153 3220 6813