Factory-Direct Supply of Certified Wires and Conductors for Diverse Industrial Applications
Triplex Cable Aluminum Conductor Overhead Service Drop Cable Wire 600V
Voltage: 600V (120/240V single-phase three-wire)
Phase Conductors: 2× 1350-H19 Al, solid/7-str/19-str, XLPE insulated
Insulation: 45/60/80 mils (1.14/1.52/2.03mm) black XLPE
Neutral Messenger: Bare AAC/ACSR/6201-T81 alloy
Application: Overhead residential & light commercial service drops
Ampacity: 70-420A XLPE (6 AWG to 336.4 kcmil)
Package: Export wooden reel or coil
Product Overview
Triplex Cable Aluminum Conductor Overhead Service Drop 600V is a neutral-supported overhead service cable consisting of two XLPE-insulated aluminium phase conductors twisted around a bare neutral messenger wire. The triplex configuration is the standard 120/240V residential service drop in North American and export utility markets — two 120V phase legs plus a grounded neutral provide both voltages at the service entrance. The neutral messenger serves double duty: return current path AND structural support for the span between the pole and building attachment point. Available with three messenger types: AAC (all-aluminium, standard duty), ACSR (steel-reinforced, heavy-duty for long spans), and 6201-T81 alloy (high-strength, corrosion-resistant for coastal and long-span applications).
Neutral Messenger Selection Guide
| Messenger | Strength (6 AWG) | Corrosion | Span Capability | Best For |
|---|---|---|---|---|
| AAC (1350-H19) | 563 lbs — reference | Good | Standard 8-25m | General residential, coastal |
| ACSR (steel core) | 1,190 lbs — 2.1× | Good (galvanized) | Long 25-50m | Rural spans, ice loading |
| 6201-T81 Alloy | 1,110 lbs — 2× | Excellent | Long 25-50m | Coastal, corrosive environments |

Phase Conductors (×2) — 1350-H19 Al, XLPE insulated, black
Neutral Messenger — Bare AAC/ACSR/6201 alloy, carries full span tension
Triplex Assembly — Two phases twisted around neutral, single-cable service entrance
Applicable Standards
| Standard | Scope |
|---|---|
| ASTM B-230 | 1350-H19 aluminum wire. Governs AAC phase and neutral conductor properties. |
| ASTM B-231 | Concentric-lay-stranded aluminum conductors (AAC). |
| ASTM B-232 | ACSR conductor specification for steel-reinforced neutral messenger. |
| ASTM B-399 | 6201-T81 aluminum alloy conductors (AAAC). |
| ICEA S-76-474 | Primary standard for neutral-supported power cable assemblies rated 600V. |
Technical Specifications — Aluminum Triplex Service Drop 600V
Phase: 1350-H19 Al, solid/7-strand/19-strand. Insulation: 45 mils (1.14mm) or 60 mils (1.52mm) or 80 mils (2.03mm) XLPE. Neutral: AAC/ACSR/6201 alloy. Weights: lbs/1000ft × 1.488 = kg/km. Ampacity: XLPE 90°C / Poly 75°C, 40°C ambient, 2 ft/s wind.
| Code Word | Phase AWG x Strands | Insul. (mils) | Neutral AWG (Messenger) | Neutral Str (lbs) | Wt PE (lbs/1000ft) | Wt XLPE (lbs/1000ft) | A PE | A XLP |
|---|---|---|---|---|---|---|---|---|
| AAC Neutral-Messenger (1350-H19) | ||||||||
| Patella | 6×7 | 45 | 6×7 AAC | 563 | 103 | 103 | 70 | 85 |
| Oyster | 4×7 | 45 | 4×7 AAC | 881 | 156 | 160 | 90 | 115 |
| Clam | 2×7 | 45 | 2×7 AAC | 1350 | 232 | 238 | 120 | 150 |
| Murex | 1/0×7 | 60 | 1/0×7 AAC | 1990 | 373 | 383 | 160 | 205 |
| Purpura | 1/0×19 | 60 | 1/0×7 AAC | 1990 | 370 | 380 | 160 | 205 |
| Nassa | 2/0×7 | 60 | 2/0×7 AAC | 2510 | 461 | 472 | 185 | 235 |
| Trophon | 2/0×19 | 60 | 2/0×7 AAC | 2510 | 456 | 467 | 185 | 235 |
| Melita | 3/0×19 | 60 | 3/0×19 AAC | 3310 | 562 | 562 | 215 | 275 |
| Portunus | 4/0×19 | 60 | 4/0×19 AAC | 4020 | 696 | 696 | 245 | 315 |
| Nannynose | 336.4×19 | 80 | 336.4×19 AAC | 6146 | 1118 | 1118 | 325 | 420 |
| ACSR Neutral-Messenger (Steel Reinforced) | ||||||||
| Paludina | 6×1 | 45 | 6×6/1 ACSR | 1190 | 109 | 110 | 70 | 85 |
| Voluta | 6×7 | 45 | 6×6/1 ACSR | 1190 | 116 | 118 | 70 | 85 |
| Scallop | 4×1 | 45 | 6×6/1 ACSR | 1190 | 143 | 146 | 90 | 115 |
| Whelk | 4×1 | 45 | 4×6/1 ACSR | 1860 | 165 | 169 | 90 | 115 |
| Strombus | 4×7 | 45 | 6×6/1 ACSR | 1190 | 156 | 160 | 90 | 115 |
| Periwinkle | 4×7 | 45 | 4×6/1 ACSR | 1860 | 172 | 176 | 90 | 115 |
| Cockle | 2×7 | 45 | 4×6/1 ACSR | 1860 | 227 | 233 | 120 | 150 |
| Conch | 2×7 | 45 | 2×6/1 ACSR | 2850 | 261 | 267 | 120 | 150 |
| Janthina | 1/0×7 | 60 | 2×6/1 ACSR | 2853 | 365 | 376 | 160 | 205 |
| Neritina | 1/0×7 | 60 | 1/0×6/1 ACSR | 4380 | 419 | 430 | 160 | 205 |
| Ranella | 1/0×19 | 60 | 2×6/1 ACSR | 2853 | 362 | 372 | 160 | 205 |
| Cenia | 1/0×19 | 60 | 1/0×6/1 ACSR | 4380 | 416 | 428 | 160 | 205 |
| Cavolinia | 2/0×7 | 60 | 1×6/1 ACSR | 3550 | 451 | 462 | 185 | 235 |
| Runcina | 2/0×7 | 60 | 2/0×6/1 ACSR | 5310 | 519 | 530 | 185 | 235 |
| Clio | 2/0×19 | 60 | 1×6/1 ACSR | 3550 | 437 | 444 | 185 | 235 |
| Triton | 2/0×19 | 60 | 2/0×6/1 ACSR | 5310 | 514 | 526 | 185 | 235 |
| Aega | 3/0×19 | 60 | 1/0×6/1 ACSR | 4380 | 549 | 559 | 215 | 275 |
| Mursia | 3/0×19 | 60 | 3/0×6/1 ACSR | 6620 | 626 | 633 | 215 | 275 |
| Cerapus | 4/0×19 | 60 | 2/0×6/1 ACSR | 5310 | 670 | 678 | 245 | 315 |
| Zuzara | 4/0×19 | 60 | 4/0×6/1 ACSR | 8350 | 777 | 785 | 245 | 315 |
| Limpet | 336.4×19 | 80 | 336.4×18/1 ACSR | 8680 | 1147 | 1161 | 325 | 420 |
| 6201 Alloy Neutral-Messenger (AAAC) | ||||||||
| Minex | 6×1 | 45 | 6×7 AAAC | 1110 | 101 | 102 | 70 | 85 |
| Hippa | 6×7 | 45 | 6×7 AAAC | 1110 | 105 | 107 | 70 | 85 |
| Artemia | 4×1 | 45 | 6×7 AAAC | 1110 | 132 | 134 | 90 | 115 |
| Prawn | 4×1 | 45 | 4×7 AAAC | 1760 | 152 | 154 | 90 | 115 |
| Crab | 4×7 | 45 | 6×7 AAAC | 1110 | 141 | 144 | 90 | 115 |
| Barnacle | 4×7 | 45 | 4×7 AAAC | 1760 | 157 | 160 | 90 | 115 |
| Solaster | 2×7 | 45 | 4×7 AAAC | 1760 | 212 | 216 | 120 | 150 |
| Shrimp | 2×7 | 45 | 2×7 AAAC | 2800 | 238 | 243 | 120 | 150 |
| Sandcrab | 1/0×7 | 60 | 2×7 AAAC | 2800 | 341 | 348 | 160 | 205 |
| Gammarus | 1/0×7 | 60 | 1/0×7 AAAC | 4460 | 384 | 390 | 160 | 205 |
| Echinus | 1/0×19 | 60 | 2×7 AAAC | 2800 | 336 | 342 | 160 | 205 |
| Leda | 1/0×19 | 60 | 1/0×7 AAAC | 4460 | 378 | 384 | 160 | 205 |
| Dungenese | 2/0×7 | 60 | 2/0×7 AAAC | 5390 | 474 | 481 | 185 | 235 |
| Cyclops | 2/0×19 | 60 | 2/0×7 AAAC | 5390 | 467 | 473 | 185 | 235 |
| Fulgar | 3/0×19 | 60 | 1/0×7 AAAC | 4460 | 518 | 525 | 215 | 275 |
| Flustra | 3/0×19 | 60 | 3/0×7 AAAC | 6790 | 588 | 596 | 215 | 275 |
| Arca | 4/0×19 | 60 | 2/0×7 AAAC | 5390 | 632 | 640 | 245 | 315 |
| Lepas | 4/0×19 | 60 | 4/0×7 AAAC | 8560 | 716 | 725 | 245 | 315 |
Packaging & Delivery
Export Wooden Reel
Plywood or wooden reels. Standard utility reel sizes for line crew deployment and service truck handling.
Coil Packaging
Smaller AWG sizes in coils. Utility-standard packaging for pole-top and service entrance installation.
Documentation
ASTM B-230/B-231/B-232/B-399 mill certificates, messenger tensile test per ICEA S-76-474.
Typical Applications — Aluminum Triplex Service Drop
Standard Residential Service
Primary application. 120/240V single-phase service from pole transformer to residential meter. Aluminium is the dominant conductor.
Multi-Family & Light Commercial
Service drops to duplexes, triplexes, apartment buildings, and small commercial units with 120/240V requirements.
Rural Long-Span Drops
ACSR or 6201 alloy neutral for extended pole-to-structure distances. Span lengths up to 50m with proper messenger sizing.
Coastal & Corrosive Zones
6201-T81 alloy or AAC neutral preferred for coastal installations where galvanized ACSR steel core may corrode.
Service Upgrades
Replacing undersized or deteriorated existing drops. Aluminum triplex is lighter than copper — easier handling on pole-top work.
Temporary Construction Power
Quick-deploy overhead service to construction trailers and job-site panels. Rapid installation and removal.
Request a Quote
Frequently Asked Questions
As a factory, we offer flexible MOQ depending on the cable type. For standard stock items, MOQ is low; for customized specifications, please contact our sales team for a detailed quote.
Yes, Qiangli cables are manufactured in compliance with international standards such as UL, CE, TUV, and VDE. We provide full test reports and certificates upon request.
Absolutely. We have a dedicated R&D team that can customize cable structure, material, color, and printing to meet your specific project needs.
For standard products, lead time is usually 7-15 days. For large-scale project orders or customized products, it typically ranges from 20 to 30 days.
Yes, we provide free samples for most standard cables. You only need to cover the international courier costs. Contact us to arrange your sample shipment.