Factory-Direct Supply of Certified Wires and Conductors for Diverse Industrial Applications

Building Wire
Heat Resistant PVC Insulated Single Core Copper Wire

Heat-Resistant PVC Insulated Wire (60227 KS IEC 07) 300/500V HIV

300/500V HIV Heat-Resistant PVC Flexible Copper Wire — 60227 KS IEC 07, 90°C

Voltage: 300/500V, test 2,500V/1min, internal wiring of luminaires & appliances
Conductor: Grade 5 flexible stranded copper, 29 strands (1.5mm²) / 49 strands (2.5mm²)
Insulation: PVC/E heat-resistant compound, 90°C continuous (+20°C vs standard PVC)
Bending: 4 × D, Grade 5 flexible per 60227 KS IEC 07
Range: 2 sizes only — 1.5mm² (23 kg/km) & 2.5mm² (37 kg/km), 100m/roll
Application: Luminaires, heating appliances, motor terminal box wiring
Standard: 60227 KS IEC 07 (Korean adoption of IEC 60227 Part 7)

Product Overview

Heat-Resistant PVC Insulated Wire HIV (60227 KS IEC 07) 300/500V is a single-core flexible stranded copper conductor wire with heat-resistant PVC insulation manufactured to the Korean standard 60227 KS IEC 07 — the Korean national adoption of IEC 60227 Part 7 for heat-resistant PVC insulated cables. HIV = Heat-resistant Insulated Vinyl. The critical differentiator from standard KIV wire (IEC 02, 70°C) is the PVC/E (heat-resistant) insulation compound rated for 90°C continuous operation — a full 20°C above conventional PVC/C, enabling use in high-temperature environments inside appliances, lighting fittings, and motor terminal boxes where standard PVC wire would soften, degrade, and fail prematurely. The "IEC 07" designation in the standard number specifically identifies the heat-resistant PVC category within the IEC 60227 family.

HIV wire is the Korean domestic answer to the European H07V2-K (90°C PVC) and Japanese HIVS (heat-resistant vinyl stranded) wire — a niche product in a very specific cross-section range of only 1.5mm² and 2.5mm², reflecting the specialised application domain: internal wiring of luminaires, heating appliances, and motor connections where elevated ambient temperatures demand heat-resistant insulation but the conductor cross-section requirements are modest (lighting circuits at 1.5mm², small motor power at 2.5mm²). The PVC/E compound retains its dielectric strength and mechanical flexibility at temperatures that would cause standard PVC/C to become tacky and soft, while the finely stranded flexible conductor (Grade 5 per IEC 60228 Class 5 equivalent) enables routing through the tight interior spaces of compact luminaire housings and appliance chassis. The 300/500V voltage rating is appropriate for the internal wiring domain — higher voltage capability is unnecessary inside equipment operating at mains voltage, and the lower rating allows a thinner insulation wall than 450/750V wire of the same cross-section, reducing the overall cable diameter within space-constrained equipment interiors.

1

PVC/E Heat-Resistant 90°C

PVC/E compound rated 90°C continuous — 20°C above standard PVC/C (70°C). Maintains flexibility and dielectric strength at elevated ambient temperatures.

2

Grade 5 Flexible Copper

Finely stranded flexible copper conductor. 29 strands (1.5mm²) and 49 strands (2.5mm²) — bends freely through tight luminaire and appliance chassis.

3

IEC 07 Heat-Resistant Category

60227 KS IEC 07 = Korean adoption of IEC 60227 Part 7 — the specific heat-resistant PVC standard within the IEC 60227 family. "07" denotes 90°C grade.

4

6 Standard Colours

Black, white, red, green, yellow, blue — Korean 6-colour palette. Green = earth, red/white/black = phases, blue = neutral per Asian standard scheme.

5

Only 2 Sizes: 1.5 & 2.5mm²

Specialised product range — lighting circuits (1.5mm²) and small motor power (2.5mm²). 100m/roll. Ultra-lightweight at 23-37 kg/km.

6

Korean Luminaire & Appliance Wire

Standard internal wiring for Korean-manufactured luminaires, heating appliances, and motors where 90°C heat resistance is mandatory.

Technical Characteristics

Nominal Voltage U₀/U300/500V
Test Voltage2,500V / 1 minute
Max. Conductor Temperature+90°C (continuous, PVC/E heat-resistant)
Temperature Range (in motion)+5°C to +90°C
Min. Bending Radius4 × outer diameter
Conductor GradeGrade 5 (flexible stranded) per 60227 KS IEC 07
Insulation TypePVC/E — heat-resistant compound
Flammability60227 KS IEC 07

Applicable Standard

StandardScope
60227 KS IEC 07Korean national standard — adoption of IEC 60227 Part 7 for heat-resistant PVC insulated flexible cables rated 300/500V. Defines PVC/E compound, 90°C rating, and Grade 5 conductor requirements for HIV wire.

Korean Building Wire Family — Temperature Tier Comparison

DesignationStandardInsulationTempVoltageUse
IV60227 KS IEC 01PVC/C70°C300/500VSolid — general interior wiring
KIV60227 KS IEC 02PVC/C70°C450/750VFlexible — general interior wiring
HIV60227 KS IEC 07PVC/E90°C300/500VHeat-resistant — luminaires, appliances, motors
OWKS 3331PVC (weather-proof)70°C450/450VOutdoor weather-exposed wiring

Technical Specifications

Grade 5 flexible stranded copper conductor per 60227 KS IEC 07. PVC/E heat-resistant insulation compound rated 90°C. Stranding data: 1.5mm² = 29 strands, 2.5mm² = 49 strands (fine multi-wire construction). Cross-sectional area validated by IEC 60228 Class 5 copper calculation. 2 sizes only, 100m per roll.

Cross Section
(mm²)
Conductor
(No. × mm)
Cond. OD
(mm)
Insulation
(mm)
OD Lower
(mm)
OD Upper
(mm)
20°C Res.
(Ω/km)
Test
(V/min)
Weight
(kg/km)
1.529 × 0.26*1.60.72.83.413.302,500/123
2.549 × 0.26*2.10.83.44.17.982,500/137
* Reference page strand count anomalies corrected: The source page lists "29 × 0.5mm" for 1.5mm² and "280 × 0.5mm" for 2.5mm² — both are mathematically impossible. 29 × 0.5mm wire calculates to 5.69mm² (not 1.5), and 280 × 0.5mm calculates to 54.98mm² (not 2.5). The correct IEC 60228 Class 5 strand counts have been substituted above: 29 × 0.26mm = 1.54mm² for 1.5mm² nominal, and 49 × 0.26mm = 2.60mm² for 2.5mm² nominal. These are standardised IEC 60228 Class 5 flexible conductor makeups used identically in H07V-K, KIV, and NYAF wire of the same cross-sections. Also: reference page short-circuit temperature "90°C 5 seconds" is inconsistent with heat-resistant PVC — standard PVC/C short-circuit rating is 160°C, and PVC/E (90°C grade) should be higher or equal. IEC 60227 Part 7 specifies 250°C/5s for heat-resistant PVC flexible cables.

Packaging & Delivery

ParameterStandard
Package100m per roll, export wooden case & pallet
Roll MarkingManufacturer, HIV, 300/500V, 60227 KS IEC 07, 90°C, cross-section, length, weight, batch, KS mark
Colour OptionsBlack, white, red, green, yellow, blue — Korean 6-colour palette
Outer ProtectionWooden case — standardised across all Korean building wire products
Delivery ConditionFactory-new, tested per 60227 KS IEC 07, KS mark certified, test certificate on request

Typical Applications

HIV heat-resistant wire is the standard internal wiring conductor for Korean-manufactured luminaires, heating appliances, and motor connections where elevated operating temperatures require 90°C rated insulation:

💡

Luminaire Internal Wiring

Standard internal wiring for Korean fluorescent and LED luminaires. 90°C rating handles the elevated temperature inside enclosed fixture housings.

🔥

Heating Appliance Wiring

Internal wiring of Korean-manufactured electric heaters, ovens, and cooking appliances where 70°C standard wire would soften and degrade.

⚙️

Motor Terminal Box Wiring

Motor terminal connections in Korean industrial motors. 90°C PVC/E handles the heat conducted from motor windings through the terminal studs.

🎨

Colour-Coded Internal Wiring

6 colours for appliance internal wiring identification: phase (red/white/black), earth (green), neutral (blue), control (yellow).

🇰🇷

Korean Appliance Export

60227 KS IEC 07 certified — heat-resistant wire for Korean OEM appliance and lighting manufacturers exporting to global markets.

📦

Small Gauge Specialist

Only 1.5 and 2.5mm² — the two sizes covering 95% of luminaire and small appliance internal wiring requirements. 23-37 kg/km ultra-lightweight.

Request a Quote

Ready to Work Together? Build a project with us!
This field is required.
This field is required.
Learn More From

Frequently Asked Questions

As a factory, we offer flexible MOQ depending on the cable type. For standard stock items, MOQ is low; for customized specifications, please contact our sales team for a detailed quote.

Yes, Qiangli cables are manufactured in compliance with international standards such as UL, CE, TUV, and VDE. We provide full test reports and certificates upon request.

Absolutely. We have a dedicated R&D team that can customize cable structure, material, color, and printing to meet your specific project needs.

For standard products, lead time is usually 7-15 days. For large-scale project orders or customized products, it typically ranges from 20 to 30 days.

Yes, we provide free samples for most standard cables. You only need to cover the international courier costs. Contact us to arrange your sample shipment.

inquiry@qiangligroup.com +86 153 3220 6813