Bare Conductor
AAC all aluminum stranded bare conductor for overhead line, CSA C49 Canadian standard

AAC-All Aluminum Stranded Conductor CSA C49

AAC All Aluminum Conductor CSA C49 | Canadian Standard | 4 AWG–1800 MCM | 61% IACS

Standard: CSA C49 (Aluminum Conductors, Bare, Stranded — Canadian Standards Association)

Conductor Material: Hard-drawn aluminium 1350-H19 (≥ 99.55% Al)

Conductivity: 61% IACS

Class: AA (bare overhead) / A (covered/flexible bare)

Construction: Concentric-lay stranded, circular cross-section

Size Range: 4 AWG (21.16 mm²) to 1800 MCM (912.06 mm²) — 49 sizes

Standard Wire Counts: 7 / 19 / 37 / 61 wires

Max. Continuous Temperature: 75 °C

Packaging: Wooden / steel drum; 500 m / 1000 m standard

Product Overview

AAC — All Aluminum Stranded Conductor (CSA C49) is a concentric-lay stranded bare aluminium overhead conductor manufactured to the Canadian Standards Association standard CSA C49 — the definitive overhead bare conductor specification for Canadian utility networks. Produced from hard-drawn aluminium 1350-H19 (minimum 99.55% purity), CSA C49 AAC shares the same flower code word naming convention as ASTM B231 but includes a number of Canadian-specific conductor sizes (such as Lily 3 AWG, and round-number MCM sizes 400, 550, 800, 1100, 1200, 1300, 1400, 1500, 1600, 1700, 1800 MCM) that are standard in Canadian utility procurement but absent from the US ASTM B231 table.

A key distinction of the CSA C49 data sheet is the inclusion of current rating (ampacity) values for each conductor size — making it more directly usable for distribution line design than the ASTM B231 table which does not include ampacity. The conductor is classified as Class AA (bare overhead, least flexible) and Class A (covered or flexible bare service), with the same concentric-lay construction as ASTM B231. Available from 4 AWG (Rose) to 1800 MCM, covering the complete range of Canadian distribution and transmission conductor requirements.

1

CSA C49 Certified — Canadian Standard

Full compliance with the Canadian national overhead conductor standard — mandatory for utility tender qualification, provincial utility acceptance, and Canadian Standards Association certified project submissions across all Canadian provinces and territories.

2

Canadian-Specific Size Series

Includes round-number MCM sizes (400, 550, 800, 1100, 1200, 1300, 1400, 1500, 1600, 1700, 1800 MCM) and Lily 3 AWG — standard Canadian utility conductor sizes absent from ASTM B231, required for exact-match replacement on Canadian-designed overhead infrastructure.

3

Ampacity Included in Data Table

CSA C49 specifies current rating values for each conductor size — directly usable in distribution line design calculations. The table covers 104 A (Rose, 4 AWG) to 975 A (1800 MCM), providing utility engineers with a complete design reference without additional ampacity calculation.

4

61% IACS Conductivity

Hard-drawn 1350-H19 aluminium delivers 61% IACS conductivity — maximum current-carrying capacity for a given conductor cross-section, critical in Canadian urban distribution networks where conductor size and pole loading must be minimised.

5

Flower Code Word Procurement

Shares the Aluminum Association flower code word convention with ASTM B231 — Rose, Tulip, Marigold, and other names are used identically in Canadian utility specifications. Specifying the code word eliminates AWG/MCM conversion ambiguity in procurement documents.

6

No Steel Core — Corrosion Resistant

All-aluminium construction eliminates the galvanic corrosion risk at the bimetallic interface present in ACSR. Preferred in coastal British Columbia, humid Ontario, and salt-spray environments along Canadian coastlines and near major water bodies.

Technical Specifications

Basic Parameters

StandardCSA C49 — Aluminum Conductors, Bare, Stranded (Canadian Standards Association)
Conductor MaterialHard-drawn aluminium 1350-H19 (≥ 99.55% Al purity)
Conductivity61% IACS
Class DesignationsClass AA (bare overhead, least flexible); Class A (covered/flexible bare)
ConstructionConcentric-lay stranded, circular cross-section; adjacent layers in reverse lay directions
Size Range4 AWG (21.16 mm²) to 1800 MCM (912.06 mm²)
Standard Wire Counts7 / 19 / 37 / 61 wires
Max. Continuous Temperature75 °C (continuous bare overhead service)
PackagingWooden or steel drum; standard lengths 500 m / 1000 m; custom lengths available

Full Parameter Table — CSA C49 AAC

Code WordSize (AWG/MCM)Area (mm²)Stranding (No./mm)Overall Ø (mm)Weight (kg/km)Breaking Load (kN)DC Resistance (Ω/km, 20°C)Current Rating (A)
Rose421.167/1.965.89584.101.3510104
Lily326.657/2.206.61735.001.0720124
Iris233.617/2.477.42926.200.8497136
Pansy142.397/2.778.331167.600.6739157
Poppy1/053.487/3.129.361469.200.5341180
Aster2/067.427/3.5010.5118411.600.4236207
Phlox3/085.037/3.9311.8023214.100.3360237
Oxlip4/0107.237/4.4113.2529317.700.2664273
Valerian250126.7119/2.9114.5734822.300.2274305
Daisy266.8135.167/4.9614.9036922.400.2113313
Laurel266.8135.1619/3.0115.0537223.800.2129317
Peony300152.0019/3.1915.9741726.200.1880340
Tulip336.4170.4519/3.3816.9146729.400.1638364
Daffodil350177.3519/3.4417.2448830.600.1624373
Canna397.5201.4219/3.6718.3655434.000.1427401
400202.7119/3.6818.4355834.200.1421402
Goldentuft450228.0019/3.9019.5562637.700.1263432
Cosmos477241.6819/4.0220.1266440.000.1188447
Zinnia500253.3519/4.1220.6069541.900.1132459
550278.7137/3.0921.6776848.000.1033485
Dahlia556.5282.0019/4.3421.7377446.700.1018489
Meadowsweet600304.0037/3.2322.6383852.400.0948513
Orchid636322.2637/3.3323.3188855.600.0896531
Heuchera650329.3537/3.3623.5690856.800.0876538
Verbena700354.7137/3.4924.4597861.100.0814562
Violet715.5362.5837/3.5324.74100062.500.0797570
Petunia750380.0037/3.6125.32104864.200.0758585
Arbutus795402.8437/3.7226.06111268.100.0715605
800405.3537/3.7326.14111868.500.0712608
Anemone874.5443.1037/3.9027.33122273.300.0653641
Cockscomb900456.0637/3.9627.73125775.400.0633657
Magnolia954483.4237/4.0728.55133380.000.0597675
Hawkweed1000506.7137/4.1729.23139683.800.0568693
Bluebell1033.5523.6837/4.2429.72144586.600.0551706
1100557.3561/3.4130.70153996.100.0518733
Marigold1113563.9361/3.4330.89155997.200.0512738
Hawthorn1192.5604.2661/3.5531.951670104.100.0479767
1200608.0661/3.5632.081679102.700.0476771
Narcissus1272644.5161/3.6633.021781108.800.0450797
1300658.7161/3.7033.371818111.200.0440807
Columbine1351.5684.8461/3.7834.011893115.600.0423825
1400709.4261/3.8434.631958117.400.0407842
Carnation1431725.1061/3.8935.032004119.900.0400854
1500760.0661/3.9835.852098125.700.0381877
Gladiolus1510.5765.3561/3.9935.992116126.500.0377881
Coreopsis1590.5805.6861/4.0936.912226133.200.0358907
1600810.7161/4.1137.042238134.100.0358910
1700861.4261/4.2338.152378142.600.0335942
1800912.0661/3.5739.282521153.900.0316975
Current ratings are tabulated values per CSA C49 under standard ambient conditions. Actual line ampacity must be verified by project-specific thermal rating calculations considering local ambient temperature, wind speed, solar radiation, and maximum allowable conductor temperature. Sizes marked "—" (no code word) are Canadian-specific round-number MCM sizes used in utility procurement without a flower code word designation. Lily (3 AWG) is a Canadian-specific size not present in the ASTM B231 table.

Key Features & Technical Advantages

1

CSA C49 Compliance — Canadian Regulatory Acceptance

CSA C49 certification is required for conductor procurement by Canadian utilities (Hydro-Québec, BC Hydro, Ontario Hydro, SaskPower, Manitoba Hydro, and others) and for projects subject to Canadian Electrical Code (CEC) and provincial utility regulations.

2

Includes Current Rating Table

Unlike ASTM B231 which omits ampacity, CSA C49 includes tabulated current rating values for every conductor size — a significant advantage for distribution line engineers who need a single-source design reference without additional CIGRE or IEEE thermal calculations for standard applications.

3

Canadian-Specific Round MCM Sizes

Round-number MCM sizes (400, 550, 800, 1100, 1200, 1300, 1400, 1500, 1600, 1700, 1800 MCM) are standard in Canadian utility infrastructure and absent from ASTM B231. These sizes are required for exact conductor replacement on existing Canadian-design overhead lines.

4

Lily 3 AWG — Canada-Only Size

Lily (3 AWG, 26.65 mm²) fills the gap between Rose (4 AWG) and Iris (2 AWG) — used in Canadian residential service drop and light distribution applications. This size is not listed in ASTM B231 and is unique to CSA C49 procurement.

5

Identical Material to ASTM B231

Same 1350-H19 hard-drawn aluminium, same 61% IACS conductivity, same concentric-lay construction as ASTM B231 — the CSA standard differs in its size series, ampacity table, and Canadian testing requirements, not in conductor material or electrical performance.

6

Cold-Climate Performance

Hard-drawn 1350-H19 aluminium maintains its mechanical properties at Canadian sub-arctic temperatures. The conductor's rated tensile strength applies across the operating temperature range from −40 °C winter extremes to +75 °C summer peak conductor temperatures.

CSA C49 vs ASTM B231 — Key Differences

ParameterCSA C49 (Canadian)ASTM B231 (US)
Primary marketCanada (all provinces)USA, Mexico, Latin America
Ampacity table includedYes — in standard data tableNo — calculated separately per IEEE 738
Canada-specific sizesYes — 400, 550, 800, 1100–1800 MCM; Lily 3 AWGNo
Flower code wordsSame convention (Aluminum Association Pub. 50)Same convention
Conductor material1350-H19, ≥ 99.55% Al1350-H19 per ASTM B230
Max. continuous temp.75 °C75 °C
Cross-referenceCompatible with ASTM B231 shared sizesCompatible with CSA C49 shared sizes

Certifications & Standards

CSA C491350-H19 Aluminium61% IACSClass AA / Class A4 AWG – 1800 MCMCSA Certified

Typical Applications

🍁

Canadian Utility Distribution

Primary distribution feeders (4–25 kV) for Hydro-Québec, BC Hydro, Ontario Hydro, SaskPower, and other provincial utilities — the primary application for CSA C49 AAC.

🏠

Residential Service Drops

Small-size CSA AAC (Rose 4 AWG to Lily 3 AWG to Oxlip 4/0 AWG) for residential and light commercial service connections in Canadian distribution systems.

HV Transmission Lines

Large CSA sizes (1000–1800 MCM) for high-voltage 115–500 kV transmission corridors across Canadian provinces — particularly where round-MCM sizes are specified in existing infrastructure.

🌊

Coastal BC & Maritime Canada

All-aluminium construction preferred over ACSR in coastal British Columbia, Nova Scotia, New Brunswick, and PEI where salt air accelerates ACSR steel core corrosion.

❄️

Northern & Sub-Arctic Lines

Lines in northern Ontario, Manitoba, Saskatchewan, Alberta, and northern territories — hard-drawn 1350-H19 maintains rated mechanical properties at −40 °C winter operating temperatures.

🔁

Canadian Line Replacement

Reconductoring and replacement of aged overhead lines on existing Canadian-design infrastructure — exact CSA size match ensures hardware and fitting compatibility without recalculation.

Request a Quote

Ready to Work Together? Build a project with us!
This field is required.
This field is required.
Learn More From

Frequently Asked Questions

As a factory, we offer flexible MOQ depending on the cable type. For standard stock items, MOQ is low; for customized specifications, please contact our sales team for a detailed quote.

Yes, Qiangli cables are manufactured in compliance with international standards such as UL, CE, TUV, and VDE. We provide full test reports and certificates upon request.

Absolutely. We have a dedicated R&D team that can customize cable structure, material, color, and printing to meet your specific project needs.

For standard products, lead time is usually 7-15 days. For large-scale project orders or customized products, it typically ranges from 20 to 30 days.

Yes, we provide free samples for most standard cables. You only need to cover the international courier costs. Contact us to arrange your sample shipment.

inquiry@qiangligroup.com +86 153 3220 6813