Factory-Direct Supply of Certified Wires and Conductors for Diverse Industrial Applications

Control Cable
Section display of KVV32 PVC insulated steel wire armoured SWA copper control cable for harsh installation environments

KVV32 Control Cable-PVC Insulated Steel Wire Armoured SWA Copper Cables

KVV32 Control Cable | PVC Steel Wire Armoured SWA | Direct Burial | GB/T 9330 IEC 60502

Standard: IEC 60227 / IEC 60502 / GB/T 9330 / BS 6500

Rated Voltage: 450/750V

Conductor: Soft annealed copper — solid or 7-wire stranded

Insulation: PVC

Inner Sheath: PVC

Armour: Galvanised round steel wire (SWA) — 1.25 mm (small sizes) / 1.6 mm (large sizes)

Outer Sheath: PVC (ST2), black

Conductor Sizes: 0.75 / 1.0 / 1.5 / 2.5 / 4 / 6 mm²

Core Counts: 5 / 6 / 7 / 8 / 10 / 12 / 14 / 16 / 19 / 24 / 27 / 30 / 37 / 44 / 48 / 52 / 61

Max. Conductor Temperature: +70°C continuous; +160°C short-circuit (5s)

Product Overview

KVV32 Control Cable is a copper conductor, PVC insulated, PVC inner sheathed, steel wire armoured (SWA), PVC outer sheathed control cable rated at 450/750V, manufactured to IEC 60227, IEC 60502, GB/T 9330, and BS 6500. The "32" suffix in KVV32 denotes steel wire armour — a layer of helically wound galvanised round steel wires that provides substantially superior mechanical protection to the steel tape armour of KVV22. The round steel wires form a continuous interlocked layer that resists tensile pulling, crushing, rodent attack, and lateral impact simultaneously — making KVV32 the preferred choice for direct burial in ground, routing through areas with significant mechanical hazard, and installations exposed to rodent populations.

Compared to KVV22 (steel tape armour), KVV32 offers higher tensile strength (the steel wires can carry axial load during cable pulling and in vertical drops), better crush resistance, and superior rodent protection — at the cost of a slightly larger overall diameter and heavier weight per unit length. The steel wire armour can also serve as a Circuit Protective Conductor (CPC / earth) when bonded at both ends per IEC 60364/GB 50054, eliminating the need for a separate earth core in most installations. Available in conductor sizes 0.75 mm² to 6 mm² and core counts from 2 to 61 cores.

1

Steel Wire Armour — Superior Mechanical Protection

Round galvanised steel wires wound helically over the inner sheath provide three-dimensional mechanical protection: radial crush resistance, axial tensile strength during pulling and in vertical drops, and lateral impact resistance. Superior to steel tape armour (KVV22) in all three mechanical axes.

2

Direct Burial Without Conduit

The steel wire armour provides the mechanical protection level required for direct burial in ground without additional conduit — the highest-value installation advantage of KVV32 over KVV22. Direct burial eliminates conduit material cost and installation labour, and simplifies underground control cable routing between field equipment and control buildings.

3

Rodent Attack Resistance

The round steel wire construction resists rodent gnawing — rats and mice cannot bite through the interlocked wire layer even when sustained attack is directed at a single point. KVV22 steel tape offers lower rodent resistance; KVV32 is the mandatory specification for underground control cable in areas with documented rodent populations.

4

Steel Wire as CPC

The armour steel wire layer, when bonded to earth at both termination ends, provides a continuous low-impedance earth path (CPC) throughout the cable length — eliminating the need for a dedicated earth core in most control circuit applications and simplifying panel termination and earth design.

5

GB/T 9330 + IEC + BS — Triple Standard

Multi-standard certification makes KVV32 suitable for Chinese-standard domestic projects (GB/T 9330), international projects with IEC specification (IEC 60227/60502), and Commonwealth-market projects referencing BS 6500 — a single cable product satisfies the procurement requirements of all three standard families.

6

2 to 61 Cores — Full Control System Range

The complete core count range from 2-core simple circuits to 61-core high-density PLC marshalling assemblies within a single KVV32 family — simplifying multi-cable project procurement and enabling consistent cable construction standards across all control cable runs in the same installation.

Technical Specifications

KVV Family — KVV22 vs KVV32 Selection Guide

ModelArmour TypeDirect BurialRodent ResistanceOD vs KVV22Best For
KVV22Double steel tapeLimitedModerateSmallerCable trench, conduit — radial compression only
KVV32Steel wire (SWA)✅ Yes✅ HighLargerDirect burial, rodent risk, vertical drops, pulling loads
KVVP2Steel tape screenNoLowSimilar to KVV22EMI shielding priority — indoors/trench only
KVVNoneNoNoneSmallestIndoors only, no mechanical hazard

Basic Technical Parameters

StandardIEC 60227 / IEC 60502 / GB/T 9330 / BS 6500
Rated Voltage450/750V
ConductorSoft annealed copper — solid or 7-wire stranded
InsulationPVC (colour coded per IEC 60227 / GB/T 9330)
Inner SheathPVC
ArmourGalvanised round steel wire (SWA) — helically wound single layer
Outer SheathPVC (ST2), black
Conductor Sizes0.75 / 1.0 / 1.5 / 2.5 / 4 / 6 mm²
Core Counts2 / 3 / 4 / 5 / 6 / 7 / 8 / 10 / 12 / 14 / 16 / 19 / 24 / 27 / 30 / 37 / 44 / 48 / 52 / 61
Max. Conductor Temperature+70 °C (continuous); +160 °C (short-circuit, max. 5 s)
Min. Service Temperature−15 °C
Min. Bending Radius20 × cable overall diameter
Flame RetardancyIEC 60332-1 (single wire vertical burn)
Direct BurialSuitable — steel wire armour provides adequate mechanical protection
SWA as CPCYes — steel wire armour usable as Circuit Protective Conductor
PackagingWooden drum; standard lengths 500 m / 1000 m; custom lengths available

Parameter Table — KVV32 (0.75 mm², Solid Conductor 1/0.97 mm)

Cores × Section (mm²)Insulation (mm)Inner Sheath (mm)Steel Wire Ø (mm)Outer Sheath (mm)Overall Ø (mm)Weight (kg/km)
5×0.750.61.11.251.516.10524
6×0.750.61.11.251.516.87564
7×0.750.61.11.251.516.87571
8×0.750.61.11.251.517.65608
10×0.750.61.21.251.519.33697
12×0.750.61.21.251.519.68728
14×0.750.61.21.251.520.37775
16×0.750.61.21.251.521.11827
19×0.750.61.21.251.521.89883
24×0.750.61.21.61.725.441126
27×0.750.61.21.61.725.791173
30×0.750.61.21.61.726.381233
37×0.750.61.21.61.727.701372
44×0.750.61.21.61.729.961556
48×0.750.61.21.61.730.111600
52×0.750.61.21.61.730.691673
61×0.750.61.21.61.732.021842

Parameter Table — KVV32 (0.75 mm², Stranded Conductor 7/0.37 mm)

Cores × Section (mm²)Insulation (mm)Inner Sheath (mm)Steel Wire Ø (mm)Outer Sheath (mm)Overall Ø (mm)Weight (kg/km)
5×0.750.61.11.251.516.59543
6×0.750.61.11.251.517.41585
7×0.750.61.11.251.517.41591
8×0.750.61.21.251.518.23631
10×0.750.61.21.251.520.01729
12×0.750.61.21.251.520.48762
14×0.750.61.21.251.521.21811
16×0.750.61.21.251.522.00866
19×0.750.61.21.251.522.82927
24×0.750.61.21.61.726.521185
27×0.750.61.21.61.726.891232
30×0.750.61.21.61.727.511295
37×0.750.61.21.61.728.921443
44×0.750.61.21.61.731.121625
48×0.750.61.21.61.731.491680
52×0.750.61.21.61.732.121754
61×0.750.61.21.61.733.531938
Tables show 0.75 mm² conductor sizes (solid and stranded). Conductor sizes 1.0 / 1.5 / 2.5 / 4 / 6 mm² are available across the same core count range — contact us with your required specification for a complete quotation. KVV32 overall diameter is approximately 4–5 mm larger than KVV22 of the same core count and cross-section, due to the steel wire armour layer (1.25 mm or 1.6 mm wire diameter) being thicker than the steel tape (0.2 mm). Specify conductor type (solid or stranded) when ordering.

Key Features & Technical Advantages

1

Three-Axis Mechanical Protection

Round steel wire armour simultaneously resists: (1) radial crushing — soil overburden or vehicle load above a buried cable; (2) axial tension — pulling forces during cable installation or weight of a vertical cable drop; (3) lateral impact — accidental striking by digging tools, falling objects, or vehicle contact. No other armour type provides all three simultaneously.

2

Direct Burial — No Conduit Required

KVV32 meets the mechanical protection requirements for direct burial in most soil conditions without additional conduit — eliminating conduit purchase and installation from the project cost. For long underground control cable runs between field equipment and control buildings, KVV32 direct burial versus KVV22 in conduit often represents significant cost savings.

3

Rodent Proof Construction

The interlocked round wire layer resists sustained rodent gnawing at any single point — the steel wire hardness and the mechanical interlocking prevent tooth penetration even under repeated attack. Mandatory for underground control cable in agricultural, food processing, grain storage, and waste water treatment facilities where rodent populations are unavoidable.

4

Tensile Strength for Vertical Drops

In mine shaft, elevator shaft, and tall building riser installations where long vertical cable drops create significant self-weight tensile loading, KVV32 steel wire armour carries the axial load — allowing longer unsupported vertical runs than KVV22 without requiring supplementary cable cleats or external support systems at frequent intervals.

5

Higher Pull-In Load Capacity

During installation through conduit, cable trays, or direct pull-in to underground ducts, KVV32's tensile armour strength permits higher pulling tensions — enabling longer horizontal pull-in distances without intermediate pull pits, and reducing the risk of insulation damage from excessive tensile stress during difficult routing.

6

IEC 60332-1 Flame Retardant

PVC insulation and sheath pass IEC 60332-1 single wire vertical flame test — self-extinguishing when the ignition source is removed. ZR-KVV32 (flame retardant) variant available for installations requiring IEC 60332-3 bundle flame test compliance in high cable density areas.

Certifications & Standards

GB/T 9330IEC 60227IEC 60502BS 6500450/750VIEC 60332-1Steel Wire Armoured (SWA)Direct Burial

Typical Applications

🌾

Direct Burial — Ground Routes

Underground control cable between field equipment (pumps, valves, sensors) and control buildings — KVV32 eliminates conduit cost for direct burial installations.

🏭

Industrial Process Control

Control and instrumentation wiring in petrochemical, chemical, water treatment, and manufacturing facilities where mechanical hazard and rodent risk are significant.

Power Plant Control

Secondary control, protection relay, and instrumentation circuits in Chinese-standard power plants — KVV32 in direct burial routes between outdoor switchgear yards and control buildings.

⛏️

Mining Applications

Control cable in mine shafts, tunnels, and surface installations — SWA tensile strength for vertical shaft drops, armour protection against mechanical damage in harsh mining environments.

🌊

Water & Wastewater Plants

Control wiring to pumps, valves, and instrumentation at water treatment and sewage treatment plants — direct burial in areas with significant rodent activity and high soil moisture.

🚈

Railway & Metro Control

Trackside control, signalling, and traction power control cable in Chinese-standard railway and metro systems — KVV32 direct burial along track routes.

🏗️

Construction Site Temporary Power

Temporary control cable for construction site plant — armour protection against site mechanical hazard and rodent populations before permanent installation.

🌏

Chinese-Standard Export Projects

GB/T 9330 + IEC dual-certified KVV32 for international infrastructure projects in Southeast Asia, Africa, and the Middle East executed by Chinese contractors.

Request a Quote

Ready to Work Together? Build a project with us!
This field is required.
This field is required.
Learn More From

Frequently Asked Questions

As a factory, we offer flexible MOQ depending on the cable type. For standard stock items, MOQ is low; for customized specifications, please contact our sales team for a detailed quote.

Yes, Qiangli cables are manufactured in compliance with international standards such as UL, CE, TUV, and VDE. We provide full test reports and certificates upon request.

Absolutely. We have a dedicated R&D team that can customize cable structure, material, color, and printing to meet your specific project needs.

For standard products, lead time is usually 7-15 days. For large-scale project orders or customized products, it typically ranges from 20 to 30 days.

Yes, we provide free samples for most standard cables. You only need to cover the international courier costs. Contact us to arrange your sample shipment.

inquiry@qiangligroup.com +86 153 3220 6813 WeChat: 173 0291 5963

Add WeChat

173 0291 5963