Factory-Direct Supply of Certified Wires and Conductors for Diverse Industrial Applications
PVC Flat Flexible Cable / Twin Flat Flexible Cable-RVVB
Standard: GB/T 5023.5 / IEC 60227-5 / EN 50525-2-11
Rated Voltage: 300/300V for H03VVH2-F; 300/500V for H05VVH2-F
Cable Profile: Flat twin, two parallel cores joined by an integral co-extruded PVC web
Conductor: Fine-stranded plain copper, Class 5 per IEC 60228 / EN 60228
Insulation: PVC, typically Type TI2, 70°C maximum conductor temperature
Outer Sheath: PVC, typically Type TM2, flat profile
Construction: Cu/PVC/PVC, no external binding tape and no separate round outer jacket
Core Colors: Red + Blue shown; Brown + Blue, Black + White, and other colors available
PVC Flat Flexible Cable / Twin Flat Flexible Cable (RVVB)
PVC Flat Flexible Cable (RVVB), also identified in international markets as H03VVH2-F or H05VVH2-F depending on the voltage grade, is a two-core parallel flexible cable for household appliances, lighting equipment, power cords, and light-duty electrical connections. It uses fine-stranded copper conductors with PVC insulation and a PVC outer sheath formed as a flat twin profile.
The two cores are laid in parallel and joined by an integral PVC connecting web. This web is co-extruded with the surrounding PVC sheath; it is not an external binding tape, braid, filler, or separate round outer jacket. The flat profile makes the cable easy to route behind appliances, under light-duty trunking, and through narrow spaces while keeping the two conductors together during installation.
The product can be supplied in two common voltage grades. H03VVH2-F is the light-duty 300/300 V version, typically used in smaller cross-sections. H05VVH2-F is the ordinary-duty 300/500 V version for higher rated voltage applications. Both versions use Cu/PVC/PVC construction and a Class 5 flexible copper conductor. The exact conductor strand count, PVC compound, color, dimensional tolerance, and certification marking should be confirmed against the production specification for the ordered size.

Red Core — Flexible stranded copper conductor with red PVC insulation
Blue Core — Flexible stranded copper conductor with blue PVC insulation
Integral PVC Web — Co-extruded connection between the two cores
Flat PVC Sheath — Outer PVC layer forms the flat twin profile and protects both cores
Technical Specifications
Basic Parameters
| Product Name | PVC Flat Flexible Cable / Twin Flat Flexible Cable / RVVB |
|---|---|
| International Designation | H03VVH2-F (300/300 V) or H05VVH2-F (300/500 V), according to ordered voltage grade |
| Construction | Cu/PVC/PVC; two parallel cores connected by an integral co-extruded PVC web |
| Conductor | Fine-stranded plain copper, Class 5 flexible conductor; IEC 60228 / EN 60228 reference |
| Insulation | PVC insulation, typically Type TI2 for the H05VVH2-F construction |
| Outer Sheath | PVC sheath, typically Type TM2 for the H05VVH2-F construction |
| Core Colors | Red + Blue shown; Brown + Blue, Black + White, and other colors available by specification |
| Rated Voltage | 300/300 V for H03VVH2-F; 300/500 V for H05VVH2-F |
| Maximum Conductor Temperature | +70 °C |
| Maximum Short-Circuit Temperature | Up to +160 °C for a short duration, subject to the applicable cable standard and installation conditions |
| AC Test Voltage | 2 kV |
| Flame Test | IEC/EN 60332-1-2 for the applicable construction |
| Minimum Bending Radius | Typically 6 × the maximum outside dimension; confirm the final value for the ordered cable design |
| Reference Standards | GB/T 5023.5 / IEC 60227-5 for applicable PVC flexible cable constructions; EN 50525-2-11 for H03/H05VVH2-F harmonized versions |
Dimensional & Electrical Data
| Type | Cross-Section (mm²) | Insulation (mm) | Sheath (mm) | Overall Dimensions W×H (mm) | Weight (kg/km) | DC Resistance (Ω/km, 20°C) | Current Rating (A, air) |
|---|---|---|---|---|---|---|---|
| H03VVH2-F | 2 × 0.5 | 0.6 | 0.8 | 3.0 × 4.9 | 30 | 39.0 | 3 |
| H03VVH2-F | 2 × 0.75 | 0.6 | 0.8 | 3.2 × 5.2 | 37 | 26.0 | 6 |
| H05VVH2-F | 2 × 0.75 | 0.6 | 0.8 | 3.7 × 6.0 | 47 | 26.0 | 6 |
| H05VVH2-F | 2 × 1.0 | 0.6 | 0.8 | 3.9 × 6.2 | 54 | 19.5 | 10 |
| H05VVH2-F | 2 × 1.5 | 0.7 | 0.8 | 4.7 × 7.6 | 73 | 13.3 | 16 |
| H05VVH2-F | 2 × 2.5 | 0.8 | 1.0 | 5.6 × 9.1 | 108 | 7.98 | 25 |
| H05VVH2-F | 2 × 4.0 | 0.8 | 1.1 | 6.3 × 10.4 | 150 | 4.95 | 32 |
Key Features
Flat Twin Profile
Parallel cores form a low-profile cable that is easier to route in narrow spaces than a round multi-core cable.
Integral PVC Connection
The cores are joined by a continuous PVC web formed during extrusion, without external wrapping or a separate outer jacket.
Class 5 Flexible Copper
Fine-stranded copper provides the flexibility required for appliance leads and light-duty movable connections.
Two-Voltage Options
H03VVH2-F 300/300 V and H05VVH2-F 300/500 V versions cover different light-duty and ordinary-duty requirements.
PVC Double Protection
PVC insulation separates the conductors electrically, while the PVC sheath protects the twin assembly from ordinary handling.
Custom Color and Length
Core colors, outer sheath color, cut length, packing, and marking can be arranged according to the purchasing specification.
Construction Details
RVVB is a flat twin cable rather than a round RVV cable. Each core has its own flexible copper conductor and PVC insulation. The two insulated cores remain parallel and are joined along their length by the same PVC sheath material, forming an integral web between the cores.
Stranded Copper Core
Flexible plain copper strands are assembled as a Class 5 conductor. The exact number and diameter of individual strands may vary by cross-section and manufacturer design.
Individual PVC Insulation
Each conductor is separately insulated before the two cores are formed into the flat twin profile.
Co-Extruded PVC Web
The central connecting web is part of the PVC sheath extrusion. It is not a tape, braid, loose filler, or external tie.
Flat Outer Profile
The width and height are specified as W × H because the product has a flat profile rather than a circular outside diameter.
Certifications & Standards
Typical Applications
Household Appliances
Power connection for lamps, fans, small appliances, and other equipment under low to medium mechanical stress.
Lighting Equipment
Flat profile helps route power cords behind lighting fixtures and through narrow installation spaces.
Office Equipment
Suitable for light-duty connections in office and electronic equipment when the selected voltage grade is appropriate.
Indoor Power Leads
Useful for dry indoor locations and temporary use in damp areas where the product and installation requirements permit.
Appliance Internal Connections
Flexible two-core construction supports tidy routing in equipment and appliance wiring assemblies.
Custom Cable Assemblies
Available for cut lengths, color combinations, markings, and finished power-cord assemblies according to order requirements.
Related Products
H1Z2Z2-K photovoltaic cable for solar DC wiring.
Figure-8 photovoltaic cable with two integral parallel cores.
Halogen-free building wire for fixed installation applications.
Request a Quote
Frequently Asked Questions
As a factory, we offer flexible MOQ depending on the cable type. For standard stock items, MOQ is low; for customized specifications, please contact our sales team for a detailed quote.
Yes, Qiangli cables are manufactured in compliance with international standards such as UL, CE, TUV, and VDE. We provide full test reports and certificates upon request.
Absolutely. We have a dedicated R&D team that can customize cable structure, material, color, and printing to meet your specific project needs.
For standard products, lead time is usually 7-15 days. For large-scale project orders or customized products, it typically ranges from 20 to 30 days.
Yes, we provide free samples for most standard cables. You only need to cover the international courier costs. Contact us to arrange your sample shipment.