Factory-Direct Supply of Certified Wires and Conductors for Diverse Industrial Applications

Building Wire

PVC Flat Flexible Cable / Twin Flat Flexible Cable-RVVB

PVC Flat Flexible Cable RVVB | H03VVH2-F / H05VVH2-F 300/500V | Twin Flat Cable

Standard: GB/T 5023.5 / IEC 60227-5 / EN 50525-2-11

Rated Voltage: 300/300V for H03VVH2-F; 300/500V for H05VVH2-F

Cable Profile: Flat twin, two parallel cores joined by an integral co-extruded PVC web

Conductor: Fine-stranded plain copper, Class 5 per IEC 60228 / EN 60228

Insulation: PVC, typically Type TI2, 70°C maximum conductor temperature

Outer Sheath: PVC, typically Type TM2, flat profile

Construction: Cu/PVC/PVC, no external binding tape and no separate round outer jacket

Core Colors: Red + Blue shown; Brown + Blue, Black + White, and other colors available

PVC Flat Flexible Cable / Twin Flat Flexible Cable (RVVB)

PVC Flat Flexible Cable (RVVB), also identified in international markets as H03VVH2-F or H05VVH2-F depending on the voltage grade, is a two-core parallel flexible cable for household appliances, lighting equipment, power cords, and light-duty electrical connections. It uses fine-stranded copper conductors with PVC insulation and a PVC outer sheath formed as a flat twin profile.

The two cores are laid in parallel and joined by an integral PVC connecting web. This web is co-extruded with the surrounding PVC sheath; it is not an external binding tape, braid, filler, or separate round outer jacket. The flat profile makes the cable easy to route behind appliances, under light-duty trunking, and through narrow spaces while keeping the two conductors together during installation.

The product can be supplied in two common voltage grades. H03VVH2-F is the light-duty 300/300 V version, typically used in smaller cross-sections. H05VVH2-F is the ordinary-duty 300/500 V version for higher rated voltage applications. Both versions use Cu/PVC/PVC construction and a Class 5 flexible copper conductor. The exact conductor strand count, PVC compound, color, dimensional tolerance, and certification marking should be confirmed against the production specification for the ordered size.

RVVB PVC flat flexible cable cross-section with two stranded copper cores, red and blue PVC insulation, and an integral white PVC connecting web

Red Core — Flexible stranded copper conductor with red PVC insulation
Blue Core — Flexible stranded copper conductor with blue PVC insulation
Integral PVC Web — Co-extruded connection between the two cores
Flat PVC Sheath — Outer PVC layer forms the flat twin profile and protects both cores

Technical Specifications

Basic Parameters

Product NamePVC Flat Flexible Cable / Twin Flat Flexible Cable / RVVB
International DesignationH03VVH2-F (300/300 V) or H05VVH2-F (300/500 V), according to ordered voltage grade
ConstructionCu/PVC/PVC; two parallel cores connected by an integral co-extruded PVC web
ConductorFine-stranded plain copper, Class 5 flexible conductor; IEC 60228 / EN 60228 reference
InsulationPVC insulation, typically Type TI2 for the H05VVH2-F construction
Outer SheathPVC sheath, typically Type TM2 for the H05VVH2-F construction
Core ColorsRed + Blue shown; Brown + Blue, Black + White, and other colors available by specification
Rated Voltage300/300 V for H03VVH2-F; 300/500 V for H05VVH2-F
Maximum Conductor Temperature+70 °C
Maximum Short-Circuit TemperatureUp to +160 °C for a short duration, subject to the applicable cable standard and installation conditions
AC Test Voltage2 kV
Flame TestIEC/EN 60332-1-2 for the applicable construction
Minimum Bending RadiusTypically 6 × the maximum outside dimension; confirm the final value for the ordered cable design
Reference StandardsGB/T 5023.5 / IEC 60227-5 for applicable PVC flexible cable constructions; EN 50525-2-11 for H03/H05VVH2-F harmonized versions

Dimensional & Electrical Data

TypeCross-Section (mm²)Insulation (mm)Sheath (mm)Overall Dimensions W×H (mm)Weight (kg/km)DC Resistance (Ω/km, 20°C)Current Rating (A, air)
H03VVH2-F2 × 0.50.60.83.0 × 4.93039.03
H03VVH2-F2 × 0.750.60.83.2 × 5.23726.06
H05VVH2-F2 × 0.750.60.83.7 × 6.04726.06
H05VVH2-F2 × 1.00.60.83.9 × 6.25419.510
H05VVH2-F2 × 1.50.70.84.7 × 7.67313.316
H05VVH2-F2 × 2.50.81.05.6 × 9.11087.9825
H05VVH2-F2 × 4.00.81.16.3 × 10.41504.9532
Data status: The resistance, weight, dimensions, and current values above are representative technical data compiled from published H03VVH2-F/H05VVH2-F cable datasheets. Insulation and sheath thicknesses are typical nominal construction values, not a substitute for the factory drawing or type-test report. Actual dimensions and weight may vary with the PVC compound, extrusion tooling, conductor design, and manufacturing tolerance. Confirm the final ordered size before issuing a compliance document.

Key Features

01

Flat Twin Profile

Parallel cores form a low-profile cable that is easier to route in narrow spaces than a round multi-core cable.

02

Integral PVC Connection

The cores are joined by a continuous PVC web formed during extrusion, without external wrapping or a separate outer jacket.

03

Class 5 Flexible Copper

Fine-stranded copper provides the flexibility required for appliance leads and light-duty movable connections.

04

Two-Voltage Options

H03VVH2-F 300/300 V and H05VVH2-F 300/500 V versions cover different light-duty and ordinary-duty requirements.

05

PVC Double Protection

PVC insulation separates the conductors electrically, while the PVC sheath protects the twin assembly from ordinary handling.

06

Custom Color and Length

Core colors, outer sheath color, cut length, packing, and marking can be arranged according to the purchasing specification.

Construction Details

RVVB is a flat twin cable rather than a round RVV cable. Each core has its own flexible copper conductor and PVC insulation. The two insulated cores remain parallel and are joined along their length by the same PVC sheath material, forming an integral web between the cores.

01

Stranded Copper Core

Flexible plain copper strands are assembled as a Class 5 conductor. The exact number and diameter of individual strands may vary by cross-section and manufacturer design.

02

Individual PVC Insulation

Each conductor is separately insulated before the two cores are formed into the flat twin profile.

03

Co-Extruded PVC Web

The central connecting web is part of the PVC sheath extrusion. It is not a tape, braid, loose filler, or external tie.

04

Flat Outer Profile

The width and height are specified as W × H because the product has a flat profile rather than a circular outside diameter.

Certifications & Standards

GB/T 5023.5IEC 60227-5EN 50525-2-11IEC 60228 Class 5IEC 60332-1-2RoHS
Do not use the standards badges above as proof of a specific certificate unless the corresponding certificate is available for the ordered product and factory. The standard designation and certification status should be matched to the actual production version.

Typical Applications

01

Household Appliances

Power connection for lamps, fans, small appliances, and other equipment under low to medium mechanical stress.

02

Lighting Equipment

Flat profile helps route power cords behind lighting fixtures and through narrow installation spaces.

03

Office Equipment

Suitable for light-duty connections in office and electronic equipment when the selected voltage grade is appropriate.

04

Indoor Power Leads

Useful for dry indoor locations and temporary use in damp areas where the product and installation requirements permit.

05

Appliance Internal Connections

Flexible two-core construction supports tidy routing in equipment and appliance wiring assemblies.

06

Custom Cable Assemblies

Available for cut lengths, color combinations, markings, and finished power-cord assemblies according to order requirements.

This PVC flat flexible cable is intended for low to medium mechanical stress. It is not a substitute for outdoor-rated, oil-resistant, water-resistant, high-temperature, armored, or continuous-flexing cable unless a matching special construction has been specified and tested.

Request a Quote

Ready to Work Together? Build a project with us!
This field is required.
This field is required.
Learn More From

Frequently Asked Questions

As a factory, we offer flexible MOQ depending on the cable type. For standard stock items, MOQ is low; for customized specifications, please contact our sales team for a detailed quote.

Yes, Qiangli cables are manufactured in compliance with international standards such as UL, CE, TUV, and VDE. We provide full test reports and certificates upon request.

Absolutely. We have a dedicated R&D team that can customize cable structure, material, color, and printing to meet your specific project needs.

For standard products, lead time is usually 7-15 days. For large-scale project orders or customized products, it typically ranges from 20 to 30 days.

Yes, we provide free samples for most standard cables. You only need to cover the international courier costs. Contact us to arrange your sample shipment.

inquiry@qiangligroup.com +86 173 0291 5963 WeChat: 173 0291 5963

Add WeChat