Building Wire
H07Z1-U solid single core LSOH insulated copper wire, rigid low smoke zero halogen installation cable

H07Z1-U Wire

450/750V H07Z1-U HFFR Thermoplastic LSOH Solid Wire — EN 50525-3-31, CPR B2ca, Class 1

Voltage: 450/750V, test 2.5kV, CPR B2ca-s1,d1,a1 Euroclass
Conductor: Class 1 solid bare copper, BS EN 60228 — simplest LSOH termination
Insulation: HFFR type TI-7 thermoplastic per EN 50363-7, 70°C continuous
Bending: 15ר flexing / 10ר static — solid wire, bend once, hold shape
Range: 4 sizes 1.5-6mm², 21-65 kg/km, 100m/roll, glass fiber sheathing option
Fire: UNE-EN 60332 + EN 60332-3-24 bunched cable test, EN 50268 smoke, EN 50267 zero halogen
Standard: BS EN 50525-3-31, CE + CPR DoP, UNE + EN + IEC triple fire certification

Product Overview

Halogen Free Wire H07Z1-U is a single-core Class 1 solid copper conductor thermoplastic LSOH building wire manufactured to BS EN 50525-3-31. The -U suffix designates a single solid bare copper core — the simplest, most cost-effective conductor form — paired with HFFR type TI-7 thermoplastic halogen-free flame retardant insulation per EN 50363-7. H07Z1-U is the solid-core companion to the flexible H07Z1-K: identical electrical and fire-safety performance (450/750V, 70°C, 160°C short-circuit, CPR B2ca-s1,d1,a1), but with a solid conductor designed for screw-down terminals and protected fixed installations where the wire, once terminated, never moves. The LSOH safety profile — zero halogen acid gas emission per UNE-EN 50267, low smoke per UNE-EN 50268, self-extinguishing per UNE-EN 60332 — makes H07Z1-U the solid LSOH wire of choice for switchboard and distribution board internal wiring in European public buildings where CPR compliance is mandatory.

The solid conductor (-U) delivers the lowest per-metre cost of any LSOH building wire — no stranding operations, simplest manufacturing process — but at the expense of flexibility. The 15×D flexing and 10×D static bending radii are wider than the 5×D of the flexible H07Z1-K, reflecting the inherent stiffness of a single solid copper core versus a multi-strand flexible bundle. For fixed installations inside equipment enclosures and protected conduits where the wire is routed once during assembly and never moved again, the wider bending radius is irrelevant — the cost advantage and zero strand-separation risk at screw terminals are the dominant selection criteria. The four-size range (1.5, 2.5, 4, 6mm²) is intentionally limited to the cross-sections most commonly used for equipment internal wiring and branch circuit connections — larger solid conductors would be impractical to bend and are therefore not manufactured in the -U variant.

H07Z1-U Cross Section — Single solid bare copper conductor with LSOH thermosetting insulation

Bare copper conductor — Single solid orange copper core, Class 1 per BS EN 60228 — no stranding, the defining feature of the -U solid LSOH wire
LSOH thermosetting insulation — Black ring, HFFR TI-7 thermoplastic per EN 50363-7, zero halogen, CPR B2ca-s1,d1,a1

1

Class 1 Solid Copper (-U)

Single solid bare copper core per BS EN 60228 Class 1. Simplest termination — no strand separation. Lowest per-metre cost in the LSOH family.

2

HFFR TI-7 Thermoplastic LSOH

Halogen Free Flame Retardant insulation per EN 50363-7. 70°C continuous, 160°C short-circuit. Zero halogen emission per UNE-EN 50267.

3

15ר / 10ר Bending

Solid conductor bending radius — bend once during assembly, hold shape forever. For protected fixed installations, not repeated flexing.

4

CPR B2ca-s1,d1,a1

EU Construction Products Regulation fire class — B2ca (limited fire), s1 (low smoke), d1 (no droplets), a1 (low acidity). Mandatory for EU public buildings.

5

4 Sizes 1.5-6mm²

Equipment internal wiring sizes only — 1.5, 2.5, 4, 6mm² (OD range 2.4-5.0mm). 100m/roll, export wooden case.

6

BS EN 50525-3-31

Current-generation European thermoplastic LSOH standard. CE marked, CPR Declaration of Performance certified — ready for EU public works tenders.

Technical Characteristics

Rated Voltage450/750V
Test Voltage2.5 kV
Max. Conductor Temperature+70°C (continuous, thermoplastic limitation)
Max. Short-Circuit Temperature+160°C (max 5 seconds)
Flexing Bending Radius15 × outer diameter
Static Bending Radius10 × outer diameter
Flexing Temperature≥ +5°C
CPR ClassificationB2ca-s1,d1,a1 per EN 50575
Fire RetardantUNE-EN 60332 / EN 60332 / IEC 60332 & UNE-EN 60332-3-24 (bunched cable test)
Smoke DensityUNE-EN 50268 / EN 50268

Applicable Standards

StandardScope
BS EN 50525-3-31European standard for halogen-free thermoplastic insulated flexible cables 450/750V. Covers H07Z1-U solid conductor LSOH building wire.
EN 50363-7Insulation compound — HFFR type TI-7 thermoplastic halogen-free flame retardant material for low voltage energy cables.
BS EN 60228 Class 1Conductor standard — solid copper conductor specification for fixed wiring applications.
UNE-EN 60332 / EN 60332 / IEC 60332Single cable vertical flame test (IEC 60332-1) + bunched cable vertical flame spread test (EN 60332-3-24) — dual fire certification.
UNE-EN 50267 / EN 50267Halogen acid gas emission — zero HCl/HF/HBr certified. Spanish (UNE) and CENELEC (EN) dual-standard testing.

LSOH Family Standards Map

TypeStandardClassInsulationTempBendRange
H07Z1-UEN 50525-3-31Class 1 (solid)HFFR TI-7 (thermo)70°C15×/10ר1.5-6mm²
H07Z1-KEN 50525-3-31Class 5 (flexible)HFFR TI-7 (thermo)70°C5×D1.5-240mm²
H05Z-U / H07Z-UVDE 0282-9Class 1 (solid)XLPE (thermoset)90°C15×/10ר0.5-10mm²
H07Z-RHD 22.9 S2Class 2 (stranded)XLPE EI5 (thermoset)90°C8×D1.5-240mm²
H05Z-K / H07Z-KHD 22.9 S2Class 5 (flexible)XLPE EI5 (thermoset)90°C8×D0.5-240mm²
HFIXKS C 3341Class 1 & 2Polyolefin90°C4×D1.5-300mm²

Technical Specifications

Class 1 solid bare copper per BS EN 60228. HFFR type TI-7 thermoplastic LSOH insulation per EN 50363-7. All 4 sizes single core, 100m per roll. Glass fiber sheathing option available on request.

Cross Section
(No. × mm²)
Insulation
(mm)
Overall Dia.
(mm)
Copper Weight
(kg/km)
Total Weight
(kg/km)
20°C Res.
(Ω/km)
1 × 1.50.72.814.420.912.1
1 × 2.50.73.42431.57.41
1 × 40.73.83847.74.61
1 × 60.74.45865.23.08
Solid LSOH — the specialist within a specialist category: H07Z1-U's four-size range may seem limited, but these four cross-sections cover approximately 80% of equipment internal wiring and branch circuit applications. 1.5mm² for lighting and control circuits, 2.5mm² for 16A socket circuits, 4mm² and 6mm² for 25A and 32A appliance circuits. The solid conductor eliminates the most common termination fault mode — loose strands under a screw terminal — which makes it the preferred LSOH wire type for switchgear manufacturers and panel builders who terminate thousands of conductors per assembly and cannot afford rework from strand-related quality issues. Note: the cross-section image labels the insulation as "thermosetting" — this appears to be a cross-section graphic reused from the H07Z-U thermoset product line. H07Z1-U per EN 50525-3-31 uses thermoplastic HFFR TI-7 insulation, not thermosetting cross-link polyolefin.

Packaging & Delivery

ParameterStandard
Package100m per roll, export wooden case & pallet; optional glass fiber sheathing for additional mechanical protection
Roll MarkingManufacturer, H07Z1-U, 450/750V, LSOH HFFR, CPR B2ca-s1,d1,a1, cross-section, length, weight, batch, CE/CPR/UNE marks
Colour OptionsStandard LSOH identification colours
Outer ProtectionWooden case
Delivery ConditionFactory-new, tested per BS EN 50525-3-31, CPR DoP certified, UNE & CE marked

Typical Applications

H07Z1-U solid LSOH wire is the specialist fixed-installation wire for European equipment and switchboard manufacturers where solid copper termination reliability and CPR compliance converge:

Switchboard Internal Wiring

Solid conductor for busbar-to-terminal connections — zero strand separation risk under screw terminals. Critical for quality-controlled switchgear assembly lines.

🏛️

EU Public Building Equipment

CPR B2ca-s1,d1,a1 certification enables use in equipment installed in European public buildings — mandatory compliance since the 2017 CPR deadline.

🔧

Panel Builder Assembly

Solid LSOH wire for volume panel assembly — lowest rework rate from strand-related terminal failures. Preferred by European panel builders for fixed internal wiring.

🔥

Triple Fire Standard Certified

UNE-EN 60332 (single cable) + EN 60332-3-24 (bunched cable) + EN 50268 (low smoke) + EN 50267 (zero halogen) — the most comprehensive LSOH fire test suite.

🇪🇺

EN 50525 Current Standard

Manufactured to the current-generation European LSOH standard — not the legacy HD 22.9 family. CPR DoP certified and traceable.

📦

Lowest Cost LSOH Wire

4 solid sizes only — the simplest LSOH manufacturing process delivers the lowest per-metre cost. Economic LSOH compliance for fixed internal wiring.

Request a Quote

Ready to Work Together? Build a project with us!
This field is required.
This field is required.
Learn More From

Frequently Asked Questions

As a factory, we offer flexible MOQ depending on the cable type. For standard stock items, MOQ is low; for customized specifications, please contact our sales team for a detailed quote.

Yes, Qiangli cables are manufactured in compliance with international standards such as UL, CE, TUV, and VDE. We provide full test reports and certificates upon request.

Absolutely. We have a dedicated R&D team that can customize cable structure, material, color, and printing to meet your specific project needs.

For standard products, lead time is usually 7-15 days. For large-scale project orders or customized products, it typically ranges from 20 to 30 days.

Yes, we provide free samples for most standard cables. You only need to cover the international courier costs. Contact us to arrange your sample shipment.

inquiry@qiangligroup.com +86 153 3220 6813