Factory-Direct Supply of Certified Wires and Conductors for Diverse Industrial Applications
10mm2 16mm2 25mm2 Green Yellow Earth Grounding Cable Wire
Conductor: Stranded bare copper, Class 2, 7-wire (0.75-400mm²)
Insulation: Green/yellow striped PVC, IEC 60446 PE colour code
Temperature: 70°C continuous, 160°C/5s short-circuit, 0-70°C operating
Usage: Protective Earth (PE) only — must never be used as phase or neutral
Bonding Sizes: 10mm² (standard), 16mm² (recommended), 25mm² (TN-C-S earthing)
Standard: IS 694, CENELEC HD 21, IEC 60227, BS 6004, DIN VDE 0281
Product Overview
Green Yellow Earth Grounding Cable Wire 10-25mm² is a single-core copper conductor PVC insulated earth/grounding wire with the distinctive green-and-yellow stripe insulation that is internationally recognised as the protective earth (PE) conductor colour per IEC 60446. Manufactured to IS 694, CENELEC HD 21, IEC 60227, BS 6004, and DIN VDE 0281, this wire provides the essential safety function in every electrical installation: the low-impedance return path that trips the circuit breaker under fault conditions, protecting both equipment and human life. The stranded bare copper conductor (Class 2 per IEC 60228) ranges from 0.75mm² to 400mm², with a focus on the 10mm², 16mm², and 25mm² sizes most commonly used for main equipotential bonding, supplementary bonding, and circuit protective conductors in both residential and industrial installations.
The PVC insulation compound is specifically formulated for 70°C continuous dry operation with a 160°C/5s short-circuit withstand, and meets the flame retardancy requirements of IEC 60332-1 / GB/T 18380.12. With a 450/750V rating for ≥1.5mm² conductors (H07V-U) and 300/500V for 0.75-1.0mm² (H05V-U), this earth wire is qualified for use in all standard building voltage classes. The minimum bending radius of 15×D (as low as 30mm for 1.0mm²) ensures easy routing through conduit bends and terminal boxes. Operating temperature range is 0°C to +70°C with a minimum installation temperature of 0°C — the same profile as the phase and neutral conductors it accompanies in every building circuit.
The green/yellow colour coding is non-negotiable in international electrical standards: this wire must be used exclusively as a protective earth conductor and must never be repurposed as a phase or neutral conductor. Electricians and panel builders specify green/yellow earth wire alongside phase (brown/black/grey) and neutral (blue) wires to build complete, code-compliant circuits. For main equipotential bonding — the heavy-gauge earth connection linking gas/water pipes to the main earth terminal — 10mm² and 16mm² are the standard sizes per IEC 60364 and BS 7671.

Insulation — Green/yellow striped PVC, international PE colour code per IEC 60446
Conductor — 7-strand bare copper, stranded Class 2 per IEC 60228
Stripped-End View — Photograph shows exposed copper strands (棕红色/reddish-brown) where insulation has been removed for termination
Stranded Copper Conductor
Class 2 stranded bare copper, 0.75-400mm². 7-strand up to 25mm², multi-strand for larger sizes. Flexible routing in conduit and trunking.
Green/Yellow PVC Insulation
Internationally recognised PE colour per IEC 60446. PVC compound, 70°C continuous, 160°C/5s short-circuit. Flame retardant per IEC 60332-1.
H05V-U / H07V-U Type
Harmonised European designation: H05V-U (300/500V, 0.75-1.0mm²), H07V-U (450/750V, 1.5-400mm²). Solid or stranded conductor.
Protective Earth (PE) Only
Green/yellow insulation is reserved exclusively for earth/ground conductors per all international wiring codes. Must never be used as phase or neutral.
Main Bonding 10-25mm²
10mm² (standard) and 16mm² (recommended) for main equipotential bonding per IEC 60364 / BS 7671. 25mm² for TN-C-S earthing conductors.
IS 694 + 5 Standards
Indian IS 694, CENELEC HD 21, IEC 60227, BS 6004, DIN VDE 0281. Accepted across India, EU, UK, Middle East, and Commonwealth markets.
Technical Characteristics
| Rated Voltage (H07V-U) | 450/750V (≥1.5mm²) |
| Rated Voltage (H05V-U) | 300/500V (0.75-1.0mm²) |
| Test Voltage | 2.5kV for 5 minutes |
| Max. Conductor Temperature | +70°C (continuous) |
| Max. Short-Circuit Temperature | +160°C (max 5 seconds) |
| Operating Temperature Range | 0°C to +70°C |
| Min. Bending Radius | 15 × overall diameter |
| Flame Retardance | IEC 60332-1 / GB/T 18380.12 / EN 50265-2-1 |
Applicable Standards
| Standard | Scope |
|---|---|
| IS 694 | Indian Standard for PVC insulated cables for working voltages up to and including 1100V. Primary standard for the Indian subcontinent market. |
| CENELEC HD 21 | Harmonised European document for PVC insulated cables rated up to 450/750V. Covers H05V-U and H07V-U type designations. |
| IEC 60227 | International standard for PVC insulated cables. Chinese equivalent: GB/T 5023. |
| BS 6004 | British Standard for PVC insulated cables (non-armoured) for electric power and lighting up to 450/750V. |
| DIN VDE 0281 | German national standard for PVC insulated cables. Part of the VDE harmonised European cable standards system. |
Technical Specifications
Bare copper conductor, stranded Class 2 per IEC 60228. PVC insulation (green/yellow striped). DC resistance at 20°C per IEC 60228 copper maximum values. Weights are approximate. 19 sizes from 0.75mm² to 400mm².
| Cross Section (mm²) | Wire Structure (No. × mm) | Insulation (mm) | Overall Dia. (mm) | Weight (kg/km) | 20°C Res. (Ω/km) |
|---|---|---|---|---|---|
| 0.75 | 7 × 0.37 | 0.6 | 2.5 | 14.2 | 26.0 |
| 1.0 | 7 × 0.43 | 0.6 | 2.6 | 15.9 | 19.5 |
| 1.5 | 7 × 0.52 | 0.7 | 3.1 | 21.7 | 13.5 |
| 2.5 | 7 × 0.68 | 0.8 | 3.8 | 33.8 | 7.98 |
| 4 | 7 × 0.85 | 0.8 | 4.3 | 48.1 | 4.95 |
| 6 | 7 × 1.04 | 0.8 | 4.9 | 66.5 | 3.30 |
| 10 | 7 × 1.35 | 1.0 | 6.6 | 114.5 | 1.91 |
| 16 | 7 × 1.70 | 1.0 | 7.6 | 168.9 | 1.21 |
| 25 | 7 × 2.13 | 1.2 | 9.5 | 262.7 | 0.78 |
| 35 | 7 × 2.52 | 1.2 | 10.7 | 350.4 | 0.554 |
| 50 | 19 × 1.78 | 1.4 | 12.6 | 470.1 | 0.386 |
| 70 | 19 × 2.14 | 1.4 | 14.5 | 654.7 | 0.272 |
| 95 | 19 × 2.52 | 1.6 | 16.7 | 886.1 | 0.206 |
| 120 | 37 × 2.03 | 1.6 | 18.5 | 1,095.4 | 0.161 |
| 150 | 37 × 2.25 | 1.8 | 20.7 | 1,370.0 | 0.129 |
| 185 | 37 × 2.52 | 2.0 | 23.0 | 1,701.3 | 0.106 |
| 240 | 61 × 2.25 | 2.2 | 26.0 | 2,198.5 | 0.0801 |
| 300 | 61 × 2.52 | 2.4 | 29.2 | 2,735.1 | 0.0641 |
| 400 | 61 × 2.85 | 2.6 | 32.8 | 3,537.5 | 0.0486 |
Packaging & Delivery
| Parameter | Standard |
|---|---|
| Spool Type | Plastic spool (0.75-10mm², 100m); wooden drum (≥16mm², 500m/1000m); coil for small sizes |
| Spool Marking | Manufacturer, H05V-U/H07V-U, voltage, cross-section, green/yellow, length, weight, IS/BS/VDE marks |
| Colour | Green/yellow striped only — IEC 60446 mandatory PE colour |
| Outer Protection | Shrink-wrapped spools; carton boxes for mixed-size kits; wooden pallets for drum quantities |
| Delivery Condition | Factory-new, tested per IS 694 / BS 6004 / IEC 60227, test certificate on request |
Typical Applications
The green/yellow earth wire is the single most important safety component in any electrical installation. Without it, a fault that energises a metal appliance casing has no path to trip the breaker — leaving the next person who touches it at risk of fatal electric shock:
Main Equipotential Bonding
10-16mm² green/yellow bonding conductor connecting gas, water, and structural metalwork to the main earth terminal per IEC 60364 / BS 7671.
Circuit Protective Conductor
Earth conductor inside every lighting, socket, and appliance circuit. Same size as phase conductor per most wiring regulations.
Earth Electrode Connection
Connection from the main earth terminal to the earth electrode (ground rod, foundation earth, or grid). 16-25mm² stranded typical.
Industrial Panel Earthing
Internal earthing busbar connections in motor control centres, distribution boards, and industrial control panels.
International Code Compliant
Green/yellow is the universal earth colour per IEC 60446. Accepted in all markets: EU, UK, India, Middle East, Asia-Pacific.
Supplementary Bonding
Local bonding between exposed conductive parts in bathrooms, swimming pools, and medical locations where enhanced shock protection is required.
Related Products
Complete your electrical installation with phase, neutral, and fixture wires from our building wire range:
0.6/1kV aluminium XLPE bare twisted aerial bundle — NP 3528 certified
600V UL Listed copper PVC fixture wire, AWG 18-16 — luminaires and machine tools
0.6/1kV copper XLPE insulated PVC sheathed unarmoured — IEC 60502-1
Request a Quote
Frequently Asked Questions
As a factory, we offer flexible MOQ depending on the cable type. For standard stock items, MOQ is low; for customized specifications, please contact our sales team for a detailed quote.
Yes, Qiangli cables are manufactured in compliance with international standards such as UL, CE, TUV, and VDE. We provide full test reports and certificates upon request.
Absolutely. We have a dedicated R&D team that can customize cable structure, material, color, and printing to meet your specific project needs.
For standard products, lead time is usually 7-15 days. For large-scale project orders or customized products, it typically ranges from 20 to 30 days.
Yes, we provide free samples for most standard cables. You only need to cover the international courier costs. Contact us to arrange your sample shipment.